![Ecofit DuraStreet Series Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/ecofit/durastreet-series/durastreet-series_installation-instructions-manual_2354094004.webp)
EcoFit Lighting
8527 Bluejacket Street
Lenexa, Kansas 66214
(866) 789-9449
www.ecofitlighting.com
Page 4
Installation Instructions
DuraStreet
®
Series LED Light Engine
Step 4: Attach The DuraStreet Power Leads
(Figures 7
–9)
CONTINUED
WARNING: Make sure AC power is OFF prior to
making electrical connections. Also, make sure
that supply voltage is 120-277.
•
DuraStreet wiring connections:
o
DuraStreet Black Lead:
If a Photocell Is Used
: Attach the DuraStreet black
lead to the switched, hot lead coming from the
photocell (see Figure 8).
If a Photocell Is Not Used
: Attach the DuraStreet
black lead to the hot terminal of the existing luminaire
(see Figure 9).
o
DuraStreet White Lead
: Attach the DuraStreet white
lead to the neutral terminal block of the existing
luminaire. Note that this terminal provides a second hot
lead in 208/220/240VAC applications (see Figure 7).
o
DuraStreet Green Lead
: Attach the DuraStreet green
lead to the ground lead of the existing luminaire, or to an
existing ground lug.
•
Existing Electrical Components
: As noted above in Step
2, removing & recycling the existing ballast, capacitor, and
other electrical components is optional, but recommended.
o
If Existing Electrical Components Are Removed
:
Remove all existing leads not required for the DuraStreet
light engine.
o
If Existing Electrical Components Are Not Removed
:
Cap and secure existing leads connected to the existing
ballast and other electrical components.
F
IGURE
8
: Attach the DuraStreet power leads (with photocell)
.
If a photocell
is
used, attach the DuraStreet black lead
to the switched, hot lead coming from the photocell.
Note: Incoming power leads are omitted from the
drawing above.
Terminal Block
(Existing)
Safety Cable
(Attached)
F
IGURE
9
: Attach the DuraStreet power leads (without
photocell).
If a photocell is
not
used, attach the
DuraStreet black lead to the hot terminal of the existing
luminaire. Note: Incoming power leads are omitted from
the drawing above.
Safety Cable
(Attached)
Terminal Block
(Existing)
Photocell
Receptacle
(Existing)
Switched Hot
Lead From
Photocell
(Existing)
Step 5: Close & Latch The Luminaire Door
Frame (Figure 10)
• Close the luminaire door. Avoid pinching all wires
between the luminaire door and body.
• Reconnect the latch at the front of the luminaire.
F
IGURE
10
: Close & latch the luminaire.