Ecofit DuraStreet Series Installation Instructions Manual Download Page 4

EcoFit Lighting
8527 Bluejacket Street
Lenexa, Kansas 66214
(866) 789-9449

www.ecofitlighting.com

Page 4

Installation Instructions

DuraStreet

®

Series LED Light Engine

Step 4: Attach The DuraStreet Power Leads 

(Figures 7

–9) 

CONTINUED

WARNING: Make sure AC power is OFF prior to 
making electrical connections. Also, make sure 
that supply voltage is 120-277.

DuraStreet wiring connections:

o

DuraStreet Black Lead:

If a Photocell Is Used

: Attach the DuraStreet black 

lead to the switched, hot lead coming from the 
photocell (see Figure 8).

If a Photocell Is Not Used

: Attach the DuraStreet 

black lead to the hot terminal of the existing luminaire 
(see Figure 9).

o

DuraStreet White Lead

: Attach the DuraStreet white 

lead to the neutral terminal block of the existing 
luminaire. Note that this terminal provides a second hot 
lead in 208/220/240VAC applications (see Figure 7).

o

DuraStreet Green Lead

: Attach the DuraStreet green 

lead to the ground lead of the existing luminaire, or to an 
existing ground lug.

Existing Electrical Components

: As noted above in Step 

2, removing & recycling the existing ballast, capacitor, and 
other electrical components is optional, but recommended.

o

If Existing Electrical Components Are Removed

Remove all existing leads not required for the DuraStreet 
light engine.

o

If Existing Electrical Components Are Not Removed

Cap and secure existing leads connected to the existing 
ballast and other electrical components.

F

IGURE

8

: Attach the DuraStreet power leads (with photocell)

If a photocell 

is

used, attach the DuraStreet black lead 

to the switched, hot lead coming from the photocell. 
Note: Incoming power leads are omitted from the 
drawing above.

Terminal Block 

(Existing)

Safety Cable 

(Attached)

F

IGURE

9

: Attach the DuraStreet power leads (without 

photocell).

If a photocell is 

not

used, attach the 

DuraStreet black lead to the hot terminal of the existing 
luminaire. Note: Incoming power leads are omitted from 
the drawing above.

Safety Cable 

(Attached)

Terminal Block 

(Existing)

Photocell 

Receptacle 

(Existing)

Switched Hot 

Lead From 

Photocell 
(Existing)

Step 5: Close & Latch The Luminaire  Door 

Frame (Figure 10)

• Close the luminaire door. Avoid pinching all wires 

between the luminaire door and body.

• Reconnect the latch at the front of the luminaire.

F

IGURE

10

: Close & latch the luminaire.

Reviews: