10 

As an example, if you have a home office and you want to warm it up during 

the day on weekdays only, you can program the following times: 

 

Monday to Friday 

from   00:00   to   08:30   17°C 

from   08:30   to   17:00   21°C 
from   17:00   to   23:59   17°C 

Saturday and Sunday 

from   00:00   to   23:59   7°C

 

 

 

During normal operation, the display shows 

switching periods, the humidity, the internal 

temperature, mode of operation, 

programmed temperature & day of the 

week. The columns in the weekly program 

are displayed for alternate time intervals.  An 

example is shown in section 9 – Weekly program - examples. 

 

 

 

At the top of the display you can also show values that are not related to 

internal temperature and humidity. The values on the display can be 

changed with the Display button. For instance, with a wirelessly 

connected external sensor, you can record the external minimum and 

maximum temperatures.  

Pressing for more than 3 seconds on the display button you can delete 

the stored minimum and maximum values for the external temperature 

readings.      

 

 

 

 

.   

 

 

Once a week movement of the pin is activated to prevent the formation 

of scale on the  valve. The time and the start date can be changed  

(default is Saturday at 12:00). 

 

Press the Menu button for more than 3 seconds. 

 

Select the menu item “CAL” with the setting dial. 

 

Confirm with  OK. 

 

Select the day of the week with the setting dial. 

 

Confirm with OK. 

 

Select the time with the setting dial. 

 

Confirm with OK. 

 

 

If you have assigned a window contact to the wall thermostat, this 

lowers the temperature automatically when you ventilate the premises, 

allowing you to save on heating costs. A display shows the Window Open 
symbol 

( )

. The target temperature when the window is open, can be 

set as desired: 

 

Press the Mode button for more than 3 seconds. 

 

Select the menu item “AER” with the setting dial. 

 

 

 

 

 

 

The components of the system need to be paired so that they can 

communicate with each other by radio transmission. Proceed as follows:  

 

First set the radiator controller in the pairing mode. Read the 

instructions for this in the relevant manual.   

 

The wall thermostat transmits a radio signal. Press the OK button on 

the wall thermostat for more than 3 seconds.   

 

The display shows  “LEA”  and the pairing time remaining (up to 30 

seconds), while the wall thermostat sends a radio signal.   

 

If the controller receives the signal, its display shows “ECF”. 

The wall thermostat can be paired with different regulators. 

 

If the radio communication should be interrupted, the 

controller continues to control the temperature 

independently, according to the last setting on the wall 

thermostat.  

After you have replaced the batteries in the controller, it may 
take up to an hour and a half before the actuator receives 

new data from the wall thermostat and switches to  “ECF”. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Confirm with OK. 

 

Set the temperature with the dial.  

 

Confirm with OK. 

 

 

You can manually reset the factory settings of the wall thermostat. All 

settings made manually will be lost. 

 

Press the Menu button for more than 3 seconds. 

 

Select the menu item “RES” with the setting dial.   

 

Confirm with OK. 

 

The  display shows “ACC”, confirm with OK. 

 

 

The controls can be locked. 

 

To enable or disable the control lock , simultaneously press the  

Mode

 and 



 buttons. 

 

The  display then shows “LOC”. 

 

To de-activate the function, press both keys again. 

 

 

When the heating is turned off during the Summer, you can minimise 

reduction in battery life.  The valve is fully open and limescale 

protection remains active. 

 

To activate the heating phase, turn the setting dial clockwise if in 

manual mode (

Manu

), until the display shows “ON”. 

 

To end the function, exit manual mode or turn dial anti-clockwise. 

 

 

 

In pairing mode, up to 5 components of the system (e.g. remote 

control, window contact, external sensor) can be wirelessly connected 

to the wall thermostat.    

 

Press the OK button for more than 3 seconds. 

 

Display shows   “LEA”  and the pairing time remaining (up to 30 

seconds)   

 

The component must now be put into pairing mode (e.g. for a 

remote control, press a button).    

 

After pairing,  the assigned unit  is displayed for 3 

seconds on the wall thermostat display (RC –  remote 

control, SC – window contact, OT – outdoor temperature 

sensor).  

 

The  display will then return to normal.    

 

If the wall thermostat is already connected to 5 devices, the display 

will show “Err” if an attempt is made to add a further device. Before 

proceeding with  the assignment of a new device, you should delete 

those already assigned (see section 14). 

 

 

 

You can delete the assignment of components on the wall thermostat 

with the “UNL”  function.  All the paired components assigned are 

deleted at the same time. 

 

Press the Mode button for more than 3 seconds. 

 

Select the menu item “UNL” with the setting dial. 

 

Confirm with OK. 

 

The display shows  “ACC”, confirm with OK. 

 

 

 

 

 

 

 

 

If the room does not have to be heated, radiator valves can be closed. 

The valve is opened only in case of frost.  

Limescale protection remains active. 

 

Turn dial anti-clockwise,    decreasing temperature when in the 

manual mode  (

Manu

), until the display shows “OFF”. 

 

To end the function, exit manual mode (

Manu

) or press the right 

arrow key ( increase temperature). 

 

 

Do not throw away the device with the normal 

household waste! 

Electronic equipment must be disposed of in accordance 

with the legislation on used electrical and electronic 

equipment and be delivered to a collection point.    

The CE mark does not represent a guarantee of device  

characteristics. 

 

 

These devices are not toys, so prevent children playing with them. Do 

not leave unattended packaging material because it could pose a 

danger to children. Never open the unit as it does not contain any 

parts that can be repaired by the user. In case of damage, send it to 

the service centre. 

 

 

 

 

With the Comfort & Low Temperature(



)  button, you can simply 

switch between these two temperatures.  Factory setting 

for temperatures is 21°C and 17°C respectively, which can 

be changed in the following way: 

 

Press and hold Comfort & Reduced  (



) button. 

 

A display shows the Sun symbol  (

)  and the current comfort 

temperature. 

 

Adjust the temperature with the setting dial and  confirm with  OK. 

 

The Moon symbol  (

) appears, with the reduced temperature . 

 

Adjust the temperature with the setting dial and confirm with OK. 

Even in automatic mode, the temperature can be changed at any time 

with the button.  The temperature setting is saved until the next 

switching point of the program.  

 

 

 

If you are on holiday and want to maintain a certain temperature in 

the premises, you can use the Holiday function. 

 

Press and release the Menu button until the display shows the 

suitcase symbol (

).  

 

Then set the dial until the return time is displayed. 

 

Confirm with  OK 

 

Then set the return date with the dial. 

 

Confirm with  OK. 

 

Set the temperature with the dial and confirm with OK. 

The actuator gives a confirmation blink. The set temperature 

is stored until the set return date and time. The actuator then 

switches to automatic mode. 

 

 

 

 

 

 

 

The radio transmission takes place on a non-exclusive transmission 

channel, and interference of signal cannot be ruled out. Noise can be 

experienced from the switching on and off of electric motors in the 

vicinity.     

The signal range within buildings can be very different from that in 

open space. In addition to the transmission  and reception 

characteristics of the receiver, climatic factors such as moisture or site 

conditions have an effect.  

 

 

Power supply: 

 

3 V 

Current consumption max.: 

30 mA 

Batteries:   

 

2 off LR6 (AA/AA) 

Battery life:   

 

2 years approx. 

Display: 

 

 

LCD 

Frequency:   

 

868,3 MHz 

Range (Open): 

 

20 m 

Case size: 

 

 

78 x 98 x 28 (W x H x D) 

 

Subject to technical changes for product improvement. 

 

 

 

 

 

 

 

24. Safety instructions 

23. Disposal instructions 

22. Setting the frost protection mode 

21. Heating switched off 

20. Child lock / Key lock 

19. Reset to factory settings 

18 – Open window / ventilation function 

17. Setting the de-calcification routine 

14. Deleting paired components 

13. Pairing of wall thermostat 

15. Comfort and reduced temperature 

11. Changing the values  

26 – Specifications 

25. Guidelines for wireless mode 

16. Holiday settings 

12. Pairing the controllers wirelessly to save 

energy 

10. Display content in normal operation 

11 

15 

16 

 

12 

14 

13 

10 

Reviews: