Eco2All COMFORT DUO RF Installation Manual Download Page 8

COMFORT DUO RF

 

 10 

 

System Mode

 

1. Press "  " to change system mode. 
2. The system will enter the HEAT ->>COOL ->>> 

AUTO-mode by pressing " 

 " alternately. 

3. The HEAT mode means system enter heating 

setting mode, the LCD will show HEAT. 

4. The COOL mode means system enter cooling 

setting mode, the LCD will show COOL. 

5. AUTO mode means system enter auto setting 

mode, the LCD will show AUTO. 

 11 

 

Fan Mode

 

1. Press " 

 " to change fan mode. 

2. The system will enter the AUTO 

(“

AUTO

)

 ->> 

ON 

(“ 

ON

”) 

->>> OFF ( )mode by pressing " 

 " 

alternately.

 

7) Dimensions (unit:mm)

 

 

COMFORT DOU RF-RV 

Feature 

 

Wireless operation range is up to 30 meters 

 

Working frequency: 868 MHz 

Installation 

COMFORT DOU RF-RV 

 

Open both ends of blue 
cover by “+” screw driver 
and make the electrical 
connections according to 
the following scheme 

 

 

N: Neutral (230 V~). 

C:

 

Cooling. 

L:

 

Phase (230 V~). 

F: Fans (fancoils). 

H: Heating. 

COM:  Common.

Operating Instruction

 

RF code (ID) setting 

 

1.Check RF code to match with the transmitter’s RF 

code. Initial code setting is 0000 (All pins are 
downward). 

2.RF LED indicator (on the right next to reset):  

A. The LED will keep lighting until RF is connected. 

B. When the receives the signal, the LED will flash 

for three times. 

C. The LED will light up when it stops receiving the 

signal. 

 

Transmitter and receiver pairing: 

1. Set Home code and Room code of the transmitter. 

2. Please also set the dip switch of receiver. 

(The Home code of RF Receiver need to set as “00”. 
For the Room code setting, please refer to the below 
diagram.) 

House code=

 

 

Dimensions (unit:mm) 

 

*CDOC001954

*

CDOC001954 

03/20 

Summary of Contents for COMFORT DUO RF

Page 1: ...fort Override mode maintains the room temperature on the desired setpoint during a set period of time from 1 9 hours Manual override User settings can be retained when the thermostat is power off 2 Technical data Temperature control range 5 35 C Comfort setpoint adjustment range 5 35 C Temperature adjustment scale 0 5 C Temperature offset calibration range 3 5 C Temperature reading calibration inc...

Page 2: ...e P2 8 00 29ºC 14 ºC Return P5 18 00 25ºC 21 ºC Sleep P6 22 00 27ºC 16 ºC PROG 2 period per day Program Time Cool Heat Wake P1 6 00 25ºC 21 ºC Sleep P2 22 00 29ºC 16 ºC 4 2 LCD Display Descriptions Key lock Frost Protection Heating on Battery Low Standby Mode Run Prog Wake Run Prog Leave Run Prog Occupied Run Prog Unoccupied Run Prog Return Run Prog Sleep Setting Mode DAY MoTuWeThFrSaSu MON TUE WE...

Page 3: ...G Press the key to start programming Press to enter the program setting for day of the week SET PROG Press to enter PROG COPY function Press to return to Run PROG mode 4 1 Set PROG A Press to enter the program setting You will see Mo and P1 temperature reading is flashing Each day of the week can be individually programmed B Press the key to set desired temperature for P1 program period C Press th...

Page 4: ... for copy are completed The display returns to start PROG setting mode 5 Set Differential Press the key to select the settings for Operating mode Press to change between TPI and ANALOGE operationg mode and press to select the desired one 5 1 Analoge operating mode Once selected the Analoge operating mode press key to change value 0 5 1 1 5 2 the default value is 0 5 Press to save the changed value...

Page 5: ...oom code of your device Press to enter RF Room code setting In order to pair with RV receiver please set a code from 0 15 Attention After setting the room code please remember to set the dip switch on RV receiver For dip switch setting please refer the form below Press key to save the setting 10 Test RF signal strength of location 1 To test your devices location are good or not 2 When the ventilat...

Page 6: ...NUAL override will expire Press key to cancel the MANUAL override mode and return to Run PROG mode 3 COMFORT override COMFORT override allows you to change the temperature for a specific number of hours from one to nine without altering the thermostat s program The thermostat will use the new temperature setting for the specified amount of time then the thermostat will return to run the programmed...

Page 7: ...mostat keeps monitoring the room temperature and calls for heating should there be a risk of frost damage 1 Activate Standby function by pressing key power icon and frost protection icon will appear on LCD 2 Press the key to deactivate the Standby function and return to Run PROG mode Power icon and frost protection icon will disappear from LCD 7 Key Lock function This function allows you to lock t...

Page 8: ...ds of blue cover by screw driver and make the electrical connections according to the following scheme N Neutral 230 V C Cooling L Phase 230 V F Fans fancoils H Heating COM Common Operating Instruction RF code ID setting 1 Check RF code to match with the transmitter s RF code Initial code setting is 0000 All pins are downward 2 RF LED indicator on the right next to reset A The LED will keep lighti...

Reviews: