Eco SR Basis 2 Fitting Instructions Download Page 4

Fitting Instructions

  Door Sequence Selector ECO SR Basis 2

SYSTEMTECHNOLOGY FOR THE DOOR

www.eco-schulte.de

Fax. 0(23 73) 92 76-70

Tel. 0(23 73) 92 76-0

58706 Menden

Iserlohner Landstraße 89

ECO Schulte GmbH & Co. KG

0432-CPD-0147

EN 1158:1997

+A1:2002

3

5

7
3

1

1

4

04

ECO Schulte GmbH & Co. KG
Iserlohner Landstraße 89
D-58706 Menden

280

240

220

200

180

160

700

800

900

1000

1100

1200

1300

Width of the door leaf B in mm

D

im

e

n

si

o

n

 A

m

id

d

le

 o

th

e

 d

o

o

to

 t

h

e

  

fu

lc

ru

m

o

th

e

 d

o

o

se

q

u

e

n

c

e

 s

e

le

c

to

in

 m

m

140

120

1400

1500

600

500

260

1600

Thickness of the door leaf 60 mm

inactive leaf

active leaf

(door width B)

A

S

When establishing the dimen-
sion A provide for a safety gap

S

 of min. 30mm when  the  

inactive leaf is closing.

Whenever  the inactive leaf  is 
opened first  the pushing  flap 
MK Basis-1 must open the ac-
tive leaf at least  to  a  position
where  the  closing  sequence 
selector can keep it open. 
This is another determinating 
factor for the dimension A.

Measurements

Thickness of the door leaf 80 mm

Thickness of the door leaf 100 mm

2

0

45,5

60

120

535

Lowering

Bm8 DIN 74

ø

2

2

ø

1

8

9

3

0

Nut M8 DIN 439 SW 13

M8x20 with hexagon 

4

4

7

max. 72°

min. 30°

45

Dimension A

40

5

0

25

50

4

5

8

0

1

1

3

23

80

ø16

Door leaf

Door frame

8

,1

socket SW 4

The door sequence selector is  now  screwed  with M8x16 
hexagon  socket  screws  to  the  door  frame.  The  cylinder 
head  stud  is  destined    for    the  oblong  hole.  Please  make 
sure  that  the  door  sequence  selector  is  running  exactly 
parallel  to  the  door  lintel  when  close.  You  can  adjust  the 
horizontal position by loosening the cylinder head stud and
moving  the  door  sequence  selector  slightly  around  the 
countersunk head screw.

When in  an upright position the  telescopic  arm  must hit
exactly  on  the  pivot  of  the  support  bracket  on  the  active
leave (the last to close). The upright position of  the teles-
copic arm can be adjusted with the adjustment screw     at 
the base of the door sequence selector. Make sure that  af-
ter each adjustment the nut is properly tightened again     .
The horizontal position of the sequence selector can be ad-
justed by the 4 adjustment screws     on the fixing plate.

In order to establish the right position for the door se-
quence selector, see the chart and the sketch.

First  of  all  fix  both  support  brackets  with  the  hexagon 
socket screws (M8x16 DIN 7991) to the upper middle cor- 
ners of both door leaves. The exact dimensions for  the po-
sition can be found on the drawing.

Lubrification of the door sequence selector is not necessary.
Clean  the  door sequence selector now and then and verify
its horizontal position on the door frame and the correct up-
right position of the telescopic arm.

Maintenance: 

Installation: 

In case of any escape route or fire rating of the door these
demands must be taken into account when installing the
sequence controller. The user information should be han-
ded to the user of the unit.

Attention: 

2

3

1

4

1

3

4 x M5

2

Leistungserklärung nach Verordnung (EU) Nr. 305/2011 finden Sie unter http://www.eco-schulte.de/leistungserklaerungen
Declaration of performance according to Regulation (EU) No 305/2011 see http://www.eco-schulte.de/declarationofperformance
Déclaration des performances conformément au règlement (UE) N° 305/2011 voir http://www.eco-schulte.de/declarationdesperformances

©

 E

C

O

 S

c

h

u

lt

e

 G

m

b

H

 &

 C

o

.K

G

 /

 Ä

n

d

e

ru

n

g

e

n

 v

o

rb

e

h

a

lt

e

n

S

R

 B

a

si

2

 /

 M

T

S

1

5

0

0

8

 /

 3

3

9

2

0

6

1

0

1

 /

 I

n

d

e

x:

 b

Reviews: