8.11
Automatic adjustment of the heating setpoint
temperature
•
The setpoint temperature in heating mode can be automatically adjusted to the
outside temperature (heating curve).
•
Access conditions: Activate the automatic setting mode for the heating setpoint
temperature if parameter P22 = 1
•
Calculation formula for the heating setpoint temperature: Pset heating setpoint
temperature = 20 + (P24/10) * (P23-current ambient temperature)
The different curves represent different values of P24.
The actual value is 0.1 if P24 = 1, the base point can be set from 20-40°C with P23
8 Operating the heat pump
51