ECO REMOVAL SYSTEMS ECOGPB Instruction Manual Download Page 5

8

7

OPERATION

OPERATION

Connect hand-held unit

Connect cable to base making sure that the pins line 
up, then screw to lock in position. Do not start the 
machine until strapped on to the operators back.

Operator to place on thier back and adjust straps 
accordingly ( please see page 8 ) Do not start the 
machine until strapped on the operators back 
Important information

ALWAYS REMOVE THE HANDHELD CONTROLLER 
WHEN THE MACHINE IS NOT IN USE

Using the hand held remote 
to commence operation

• 

To commence operation make sure that the 
fluid controller is set to 0.

• 

Turn the on/off button to number 1 setting 
which turns on the battery, which starts the 
pump, the fan and the solenoid.

• 

After 5 seconds press the red button which 
ignites the burner in the lance. You will hear this 
ignite.

• 

Turn the fluid controll dial to setting 10 until you 
see detergent appear from the lance brush.

• 

Then turn the fluid control dial to setting 0 for 1 
minute while the boiler heats up.

• 

Next turn the fluid contoll dial to the required 
setting ( for gum removal set between 2-3 a 
small adjustment may be required depending 
on the surface or for a different use increase 
accordingly)

• 

Note: The fluid indicator will light up when the 
solution is empty in the backpack.

1. BATTERY CHARGE INDICATOR

2. ON OFF BUTTON

3. RED IGNITION BUTTON

4. YELLOW FLUID CONTROL DIAL

5. FLUID LEVEL INDICATOR LIGHT

1.

2.

3.

4.

5.

Adjusting the Machine

Unclip waist and chest straps. Loosen shoulder straps 
and hip belt.

Put on unit by placing arms through shoulder straps 
and secure and tighten the hip belt.

NOTE: For the most comfort, adjust unit so that the 
hip belt covers the front hipbones and the bowed-
out portion of the back padding rests on the small 
of the back.

Tighten the shoulder straps to the point where 
the unit’s weight just starts to pull down on the 
shoulders. Ideally most of the unit’s weight will 
remain on the waist.

Adjust the chest strap position to be high on the 
chest and tighten till comfortable.

Cleaning Gum

Once the machine has heated up, place the brush on 
the piece of flattened gum and wait 5-10 seconds.

Agitate the flattened gum with the brush using 
circular motions until you see gum disintegrate. Do 
not scrub or apply pressure. The weight of the lance 
with agitation is all that is required.

Remove the brush from the gum and use a broom to 
sweep across the area. Determine if all the gum has 
been removed or if more cleaning is required. 

If further cleaning is required, repeat the cleaning 
steps until gum is completely removed.

NOTE: Always complete a test patch on surfaces to 
make sure no damage occurs to the flooring  
or surface.

Summary of Contents for ECOGPB

Page 1: ...INSTRUCTION MANUAL Steam Operated Machine Original Instructions Lance weight 2 8kg ECO REMOVAL SYSTEMS Backpack fully loaded 7 5kg...

Page 2: ...systems com and click the warranty option Warranty covers parts and labour for a period of 12 months Please note this on all fair usage Please contact us to extend your warranty The Midi should be ser...

Page 3: ...wn The rechargeable battery has been designed to be fully charged BEFORE each use Only use manufacturer approved solution and fuel for the safe operation of the machine Using other consumable items in...

Page 4: ...me refer to manufacturer When red label is showing black hot the exhaust is HOT please note it will take approximately 3 minutes to heat up the boiler and the label to change to black When the black H...

Page 5: ...lution is empty in the backpack 1 BATTERY CHARGE INDICATOR 2 ON OFF BUTTON 3 RED IGNITION BUTTON 4 YELLOW FLUID CONTROL DIAL 5 FLUID LEVEL INDICATOR LIGHT 1 2 3 4 5 Adjusting the Machine Unclip waist...

Page 6: ...s ECOOSB 1 Oil Service Box 2x gas cartridges 2x detergent bottles 1x ECOOBSS brushes ECOGPB 1 General Purpose Service Box 2x gas cartridges 4x detergent bottles 1x ECOOBPP brushes ECORNB 20 Brush Roun...

Page 7: ...12 11 SAFETY DATA SHEET SAFETY DATA SHEET According to 1907 2006 EC Article 31 GUM REMOVER SOLUTION...

Page 8: ...14 13 SAFETY DATA SHEET SAFETY DATA SHEET According to 1907 2006 EC Article 31 GUM REMOVER SOLUTION...

Page 9: ...remove subject to hospital for specialised treatment Carbon Monoxide Name and description RECEPTACLES SMALL CONTAINING Ingestion Remove subject to fresh air as soon as possible and follow the guidelin...

Page 10: ...18 17 NOTES DECLARATION OF CONFORMITY READ AND SAVE THESE INSTRUCTIONS and keep with the machine at all times NOTES...

Page 11: ...19 www ecoremovalsystems com 0121 565 3087 sales ecoremovalsystems com 126 Oldbury Road Smethwick West Midlands B66 1JE...

Reviews: