20
ELECTRONIC DEMAND TIMER FEATURES, AND SERVICE, continued
service:
MANUAL INITIATED ELECTRONICS DIAGNOSTIC . . . . . . . . . . . . . . . . . . . . . . . .
1.
To enter diagnostics, press and hold the SELECT
button until (000 -- --) shows in the display.
(A)
The first 3 digits indicate water meter operation
as follows:
'
000 (steady) = soft water not in use
no flow
through the meter.
— OPEN A NEARBY SOFT WATER FAUCET —
'
000 to 199 (continual) for Models EP 6130 and EP
6225
OR
000 to 141 (continual) for Models EP 6245
and EP 6260 = repeats display for each gallon of wa-
ter passing through the meter.
If you don’t get a reading in the display, with faucet
open, pull the sensor from the valve outlet port. Pass
a small magnet back and forth in front of the sensor.
You should get a reading in the display. If you get a
reading, unhook the in and out plumbing and check
the turbine for binding.
(B)
The letter (P) and dash(es) indicate POSITION
switch operation. The letter appearing means the
switch is closed; the dash means the switch is open.
Use the RECHARGE button to manually advance
the valve into each cycle and check correct switch
operation.
CORRECT
SWITCH
DISPLAYS
VALVE CYCLE STATUS
-- --
Valve in service, fill, brining,
backwash or fast rinse position.
--
P
Valve rotating from one position
to another.
C.
While in this diagnostic screen, the following in-
formation is available and may be beneficial for vari-
ous reasons. This information is retained by the
computer from the first time electrical power is ap-
plied to the face plate.
Press the UP button to display
the number of days this face plate
has had electrical power applied.
Press the DOWN button to dis-
play the number of regenerations
initiated by this face plate since the
model code was entered.
2.
Press the SELECT button and
hold
in 3 seconds until a model
code appears in the display.
For proper softener operation, the code must be
set correctly for your model (See Table at top of
Page 4).
To reset the model code,
press the UP or DOWN
button until the correct number shows.
3.
Press SELECT to return the present time display.
If the model code was changed, make ALL the
timer settings,
pages 10 and 11.
NOTE: If the face plate is left in a diagnostic display (or a flashing
display when setting times or hardness), present time automatically
returns if a button is not pressed within 4 minutes.