background image

JINECI05 Rev. E. 11/11/2014 

 

 

CONTENTS INDEX: 

 

IMPORTANT INFORMATION……………………………………………………………………………………………… 

  3 

USER INSTRUCTIONS………………………………………………………………………………………………………… 

  5 

TECHINCAL SPECIFICATION………………………………………………………………………………………………. 

  9 

PRE INSTALLATION REQUIRMENTS…………………………………………………………………………………… 

10 

INSTALLATION INSTRUCTIONS………………………………………………………………………………………….. 

11 

COMMISSIONING AND HANDOVER………………………………………………………………………………….. 

16 

MAINTENANCE & SERVICING…………………………………..……………………………………………………….. 

17 

SPARES & STOVE CARE……………………………………………………………………………………………………… 

19 

COMMISSIONING & INSTALLATION CHECK LIST……………..……………….……………………………….. 

22 

SERVICE RECORDS…………………………………………………………………………………………………………….. 

23 

 
 
 

 

 
 
Eco-ideal Stoves, 
Emperor Way, 
Exeter Business Park, 
Exeter, 
Devon. EX1 3QS 
 
Email:     

[email protected]

 

Website: 

http://www.hunterstoves.co.uk

 

 

 
W

ARRANTY

 

Eco ideal Fires appliances come with a standard 2 
year warranty, however this excludes naturally 
wearing “consumable” components and the use of 
un-authorised fuels. 
 
 
 
 
 
 

Consumables are deemed to be; 
Glass, Seals, Gaskets, Grate Components, Log 
Retainers, Baffles and the surface finish of the 
appliance. 
 
The Warranty will only be valid if the appliance is 
installed by an appropriately qualified engineer in 
accordance with the manufacturer’s instructions 
and to the appropriate Building Regulations and/or 
Local By-Laws and serviced within 12 months of 
installation.  
 
Eco ideal will also support an extended 5 year 
warranty on external Cast Iron components such 
as Doors, Flue Collars and Covers. 
 
If this appliance is purchased through an un-
authorised stockist or an internet trader Eco-ideal 
Stoves are only obliged to support the statutory 
requirements. 
 
This appliance must be regularly serviced and 
maintained, using only Eco-ideal Stoves approved 
components for the Warranty to be valid. 
 

Summary of Contents for CVSECI05FM

Page 1: ...1 JINECI05 Rev E 11 11 2014 Eco Ideal Inset 5 MKII Model CVSECI05FM Instructions for Installation Operation Maintenance Servicing Approved for use in the United Kingdom and the Republic of Ireland...

Page 2: ...els Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles and the surface finish of the appliance The Warranty will only be valid if the appliance is installed by an...

Page 3: ...on or near this appliance Do not place furniture or other items within 1 metre of the front of this appliance See the note on material clearances on page 13 Extractor Fans and or Cooker Hoods must not...

Page 4: ...mes FUME EMISSION Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and refueling may occur Persistent fume emission must not be tolerated This applian...

Page 5: ...in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell It is non toxic but for your comfort we would suggest that during this...

Page 6: ...rols open Allow the fuel to reach a steady glow and build the fire up gradually Once you have a good fire established across the grate bed further fuel can be added as required LOADING THE APPLIANCE W...

Page 7: ...and adjust the secondary air to give the desired heat output Never leave the stove unattended until you are certain that the flames are fully established Avoid refuelling on to a low fire bed as this...

Page 8: ...otland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefor...

Page 9: ...itable for use in a shared flue Read and follow the operating instructions Use only recommended fuels This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke Con...

Page 10: ...ing the chimney flue system Make provision to access the chimney flue system for cleaning and the removal of debris If there is no existing chimney then either a prefabricated block chimney in accorda...

Page 11: ...satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulation...

Page 12: ...way It is essential that all connections between the stove and chimney flue are sealed and made airtight Both the chimney and any flue pipe must be accessible for cleaning and if ANY parts of the chi...

Page 13: ...retainer by lifting the right hand side until it will clear the opening and remove 3 Remove the catch bar front plate by lifting the right hand side until it will clear the opening and remove 4 Remove...

Page 14: ...k 7 Unscrew the 2 M6 Screws and remove the Turbo Bars 8 Pull the top edge of the Lower Side Bricks forward and remove You will now be able to remove the Lower Rear Brick 9 You can now remove the Side...

Page 15: ...the hearth or paintwork on the stove and making sure that the 12mm rope seal is compressed forming a tight seal between the stove and fireplace 4 Drill into the existing fireback through the fixing ho...

Page 16: ...appliance to heat up slowly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the Door and carry out a spillage test using a smoke ma...

Page 17: ...ese can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming of the doors could crack the glass panels The glass will not fractu...

Page 18: ...cleaner if required If the Gasket is torn or damaged we recommend that is replaced to ensure that no products of combustion enters the room when the appliance is used Brush down the outer surface and...

Page 19: ...S AND STOVE CARE Single Door Assembly Single Door HCE09008 Glass Clip HHR08146 Glass Clip Screw FSJM05008SS Single Door Glass HCE09102 Single Door Gasket HCE09101 Door Handle Assembly HCE09ARRT043S Ro...

Page 20: ...ouble Door Glass HCE09031 Double Door Gasket HCE09030 Right Hand Door HCE09009 Rope Sealing Kit SCPCB900DDRSK Glass Clip HHR08046 Glass Clip Screw FSJM05008SS Double Door Glass HCE09031 Double Door Ga...

Page 21: ...rs Side CNN05004 A B Upper CNS04013 Lower CNS04012 Ashpan HCN05ARRT033 Operating Tool HFR07040 Secondary Air Control Support Plate HCN05050 Slider Plate HH06086 Gasket HH06088 Slider Shaft HCN05016 Sl...

Page 22: ...e Appliance Description Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundnes...

Page 23: ...ervicing Company Engineer Signature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Si...

Page 24: ...24 JINECI05 Rev E 11 11 2014...

Reviews: