BEFORE YOU START

A sump pump is an electrical 

device designed to operate in 

inheretly wet environments.

ALWAYS USE EXTREME 

CAUTION

 

when installing or 

maintaining this product.

 

®

Carefully read and follow all safety  

instructions in this manual and on pump. 
SAVE THESE INSTRUCTIONS – This manual 

contains important instructions that should be 

followed during installation, operation, and  

maintenance of the product.  

Save this manual for future reference.
Safety Labels

 

 

         This is the safety alert symbol. When you 

see this symbol on your pump or in this manual, 

look for one of the following signal words and be 

alert to the potential for personal injury!
 

 

Indicates a hazard which, if 

not avoided, will result in death or serious injury.
 

 

Indicates a hazard which, 

if not avoided, could result in death or serious 

injury.
 

 

Indicates a hazard which, if 

not avoided, could result in minor or moderate 

injury.

NOTICE

 indicates practices not related to 

personal injury.
Keep safety labels in good condition. Replace 

missing or damaged safety labels.

General Safety

 

 

Risk of burns. Do not 

touch an operating motor. Motors are de-

signed to operate at high temperatures. To 

avoid burns when servicing pump, allow it to 

cool for 20 minutes after shut-down before 

handling.
Do not allow pump or any system compo-

nent to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system com-

ponents.
Wear safety glasses at all times when work-

ing on pumps.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for EPC33

Page 1: ...is symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury Indicates a hazard which if not avoided will result in death or se...

Page 2: ...th Pumped EPP33 1 3 120 1 4 0 3600 18 Thermoplastic Thermoplastic 8 3 16 EPC33 1 3 120 1 4 0 3600 18 Cast Iron Thermoplastic 8 3 16 EPP50 1 2 120 1 5 2 5000 22 Thermoplastic Nylon 8 3 8 EPC50 1 2 120...

Page 3: ...piping Drain hose galvanized steel or copper pipe may be used if desired All piping must be clean and free of all foreign matter to pre vent clogging Before installing the pump clear the sump basin o...

Page 4: ...e surface is clear of debris Never place the pump on clay earth or gravel surfaces It is recommended that the pump be placed on two bricks not included approximately 2 in apart 3 CONNECTING THE PIPE A...

Page 5: ...clogged with depris Unplug the pump to disconnect the electrical power Unscrew the screws 1 Remove the base Remove any debris from around the impeller 3 Reassemble the pump ADDITIONAL MAINTENANCE GUID...

Page 6: ...the breaker or replace the fuse If the problem continues contact a plumbing professional 2 The pump will turn on when water level reaches the appropriate depth for your switch type 3 Replug the pump...

Page 7: ...and incidental charges Claims made under this warranty shall be made by returning the product to the retail outlet where it was purchased or to the factory immediately after the discovery or any alle...