Summary of Contents for ECO2OLDT

Page 1: ...ts on how to use and maintain your dehumidifier properly Just a little preventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of Troubleshooting Tips before calling your service engineer L P ...

Page 2: ...ance as unsorted waste or with your domestic household waste Please observe local regulations for disposal Most local authorities have specific collection systems for appliances where disposals are free of charge to the end user When replacing an existing appliance with a new appliance your retailer may take back the old appliance for disposal ...

Page 3: ... PADS ON THE DEHUMIDIFIER Controlpanel 5 Otherfeatures 5 IDENTIFICATION OF PARTS Identificationof parts 6 Positioningthe unit 6 OPERA TIING THE UNIT Usingthe unit 7 Emptyingthe water tank 7 CARE AND MAINTENANCE Care and cleaning of the dehumidifier 8 TROUBLESHOOTING TIPS Troubleshootingtips 10 0 L P ...

Page 4: ...hock or fire shock or fire due to excess heat due to heat generation generation It may cause electric shock or It may cause electric shock Plastic parts may melt and cause fire due to heat generation a fire It may cause fire and electric It may cause failure of machine It may cause electrical shock or shock or electric shock injury It may cause an explosion or fire IIt contains contaminants and It...

Page 5: ...formation The manufacture s nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit The dehumidifier must be properly earthed To minimize shock and fire hazards proper earthing is important The power cord is equipped with a three pin plug for protection against shock hazards Your dehumidifier must be used in a properly grounded wall...

Page 6: ... marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 The cord grip must be positioned and fastened correctly If a 13A BS 1363 fused plug is used it m...

Page 7: ... disappears Power on indicator light This indicator light illuminates when connect to the power And flashes at 5Hz under temperature sensor malfunction O Bucket full indicator light This indicator light illuminates when the bucket is full After empty the bucket and replace in the proper position this light turns off Other features Bucket Full Light Glows when the bucket is ready to be emptied or w...

Page 8: ...ial applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full bucket of water Allow at least 20cm of air space on all sides of the unit for good air circulation Place the unit in an area where the temperature will not fall below 50C 410F The coils can become covered w...

Page 9: ...a little There are two ways to remove collected water 1 Use the bucket When the bucket is full the unit will automatically stop running and the Full indicator light will illuminate Slowly pull out the bucket Grip the left and right handles securely and carefully pull out straight so water does not spill Do not put the bucket on the floor because the bottom of the bucket is uneven Otherwise the buc...

Page 10: ... off and remove the plug from the wall outlet before cleaning 1 Clean the Grille and Case Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock cause the insulation to deteriorate or cause the unit to rust The air intake and outlet grilles get soiled easily so use a vacuum attachment or brush to clean 2 ...

Page 11: ...et the filter dry before replacing it Do not clean the filter in a dishwasher To attach Insert the air filter into the unit from the side and push it upward See Fig 0 CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance Fig A Fig B Fig C Pwr rnrd 4 When not using the unit for long time periods After turning off the unit wait one day bef...

Page 12: ...t be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes a loud a The air filter is clogged noise when operating 1111111 IThe unit is tilted instead of upright as it should be The floor surface is not level Frost appears on the 1 L coil...

Page 13: ...commended at voltages indicated on the unit Any attempts made to service or modify the unit will render this WARRANTY VOID The actual product may differ slightly from the illustration This warranty is in addition to and does not affect your statutory rights For further information please contact 020 8459 2458 This product has been manufactured to comply with the EEC Directives 73 23 EEC and 89 336...