 8

AUTO  operation

   When you set the air conditioner in AUTO mode, it will
   automatically select cooling, heating(cooling/heating
   models only), or fan only operation depending on what
   temperature you have selected and the room temperature.
   The air conditioner will control room temperature
   automatically round the temperature point set  by you.
   During very hot or cold weather, you should select either
   the COOL or HEAT modes for additional comfort.

SLEEP  operation

When you push SLEEP button on remote controller during 
cooling or heating, or AUTO operation, the air conditioner will 
automatically increase (cooling) or decrease (heating) 1

 

per hour.
 
The set temperature will be steady within 2 hours.  And the air
conditioner will be timer off in 7 hours. The fan speed will be 
automatically controlled. This feature maintains the most 
comfortable temperature, is very quiet and saves energy.

DRYING operation

The dry mode will automatically select the hehumidifying
operation based on the difference between the set
temperature and the actual room temperature.
The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or 
fan only. The fan speed indicator will display AUTO and 
low speed will be used.

Cooling

Cooling

Time

DRYING operation

Room

temperature

set temperature

Cooling

Fan only

Fan only

To achieve optimal performance, please note the following:

Adjust the air flow direction correctly so that  it is not directed 
on people.
Adjust the temperature to achieve the highest comfort level. Do 
not adjust the unit  to excessive temperature levels.
Close doors and windows on COOL or HEAT modes, or perfor-
mance may be reduced.
Use TIMER ON button on the remote controller to select a time 
you want to start your  air conditioner.

 Do not put any object near air inlet or air outlet, as the efficiency 
 of the air conditioner may be reduced and the air conditioner 
 may stop running.
 Clean the air filter periodically, otherwise cooling or heating per-
 formance may be  reduced.
 Do not operate unit with horizontal louvre in closed position.

1 hour

1 hour

Set 
Temperature

Cooling

1

1

Heating

SLEEP  operation

OPERATING INSTRUCTIONS

How the air conditioner works

Optimal operation

1

1

1 hour

1 hour

Set 
Temperature

SLEEP  operation

7 hours timer off

Summary of Contents for ECO1202SQN

Page 1: ...are on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of...

Page 2: ...ust be connected to the terminal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED...

Page 3: ...power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personn...

Page 4: ...ake back the old appliance for disposal when you replace with a new product C Old products contain valuable resources which should be recycled as scrap metal Wild disposal of waste in forests and land...

Page 5: ...y cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric...

Page 6: ...cond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off...

Page 7: ...itioner is in AUTO operation DEFROST Indicator For cooling heating model only This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature i...

Page 8: ...fan mode 3 Optimum performance will be achieved within these operating temperature Open and lift the front panel up to an angle until it remains fixed with a clicking sound Push the button until the A...

Page 9: ...w area Do not operate unit with horizontal louver in closed position When the air conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a no...

Page 10: ...mperature The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Coo...

Page 11: ...TENANCE Care and maintenance Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTE Supply power must be disconnectd before cleaning the indoor uni...

Page 12: ...edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and ci...

Page 13: ...igh relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air condi...

Page 14: ...If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit compl...

Page 15: ...plugged Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall recepta...

Page 16: ...aults arising from a faulty installation is specifically excluded This unit must be operated under conditions as recommended at voltages indicated on the unit Any attempts made to service or modify th...

Reviews: