Eco Air ECO10P Installation And Operation Manual Download Page 19

 

 

 

 

ONE (1) YEAR LIMITED WARRANTY 

SAVE THIS WARRANTY INFORMATION 

 
 

 

EcoAir  guarantees  this  product  free  from  defects  in  materials  and 
workmanship for a period of one (1) year from the date of purchase, limited 
to parts only. 
 
Faults arising from a faulty installation is specifically excluded. 
 
This  unit  must  be  operated  under  conditions  as  recommended,  at  voltages 
indicated  on  the  unit.  Any  attempts  made  to  service  or  modify  the  unit  by 
unqualified  technician,  will  render  this  WARRANTY  VOID.  The  actual 
product may differ slightly from the illustration. This warranty is in addition to, 
and does not affect, your statutory rights.  
 
For  after  sales  needs,  please  visit  www.ecoair.org/service  or  email 
[email protected] or c44 845 474 3574 

 
 
 

 
 

 

We  recommend  that  you  note  the  details  of  your  purchase  below  and  retain 
your original proof of purchase receipt with this manual. Keep these documents 
safe in the event of a warranty claim. 
 
 
Date of purchase:     

 

 _____________________________ 

 
 
Purchased from (Dealer Name):   _____________________________ 
 
 
Retailer name:         

 

 _____________________________ 

 
 
Model number:      

 

 _____________________________ 

 
 
Serial number:       

 

 _____________________________ 

 
 
Date of installation: 

 

 _____________________________ 

 

Summary of Contents for ECO10P

Page 1: ...Model information can be found on the CE label Please register your product online at www ecoair org For your future convenience record the model information below ___________________________________...

Page 2: ...trols and the most economical operation CONTENTS BS Plug Wiring 1 Specification 2 Before Use 3 Product Description 5 Installation 6 Mounting of the Exhaust Pipe 7 Installation of Carbon Filter 8 Opera...

Page 3: ...nnected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The G...

Page 4: ...240V 50Hz Compressor rotary Noise Level 53 dB Refrigerant R410A 370g Fan speed 2 Timer 1 12 hours Working temperature Cooling 18 32 o C Heating 7 25 o C Exhaust pipe 120x1500mm Net Weight 25 5 kgs Gr...

Page 5: ...SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHIL...

Page 6: ...heat and will reduce the cooling effectiveness Avoid opening doors frequently Keep curtains or blinds closed during the warmest part of the day Keep filters clean Once room has reached the desired co...

Page 7: ...Air filter 11 Air inlet 12 Water bung 13 Air outlet Accessories 14 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 15 Round cap for filling the hole in wall...

Page 8: ...ip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the...

Page 9: ...lip exhaust hose to the back of the air conditioner Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down Fig 11 12 sho...

Page 10: ...the active carbon filter from its plastic bag 4 Attach the active carbon filter to the filter frame 5 Attach the filter fixer to the filter frame the active carbon filter should be hold between the fi...

Page 11: ...3 Receiver for remote control 14 Low ventilation indicator 15 High ventilation indicator 16 Compressor operation indicator 17 Water Full indicator Turning ON OFF 1 Press ON OFF button the unit will st...

Page 12: ...s in AUTO mode it will choose the ventilation speed automatically according to the ambient temperature the related indicators will light on at this time the speed switch is invalid Setting timer 1 Pre...

Page 13: ...emperature The ventilation however keeps working on the set level If the ambient temperature rises above the selected level the cooling will return to work 3 The heating will switch off if the ambient...

Page 14: ...it when full 2 Position a container a water tray for example underneath the drain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is...

Page 15: ...drain tube Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Please refer to the instructio...

Page 16: ...eaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thoroughly before...

Page 17: ...y people in the room Is there something in the room producing lots of heat The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperatu...

Page 18: ...10P 204 19 99 Exhaust Accessories Exhaust Hose 1 5m 10P 138 24 99 Tube for continuous drainage 10P 135 6 99 Extension drainage tube 1m 10P 815 4 99 Water Bung 10P 134 6 99 Other Accessories Caster Whe...

Page 19: ...iffer slightly from the illustration This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org service or email technical ecoair org o...

Reviews: