![Eclipse EC-P50 User Manual Download Page 37](http://html1.mh-extra.com/html/eclipse/ec-p50/ec-p50_user-manual_4019692037.webp)
P0016-LU-03.01 37
4.
Touch-Tone Remote Control
Introduction
The
EC-P50
on-board communicator can be used to remotely control your alarm via any
touch-tone telephone. Once the call is answered by the control panel you will be assisted by
voice prompts to enter your normal access code, if the code is accepted a voice prompted
menu is played to you. From the main menu you can arm and disarm the system and turn
outputs on and off.
Remote Control Menu
Function Touch-Tone
Command
Away Arm
*1#
Stay Arm (1)
*2#
Disarm
*0#
Playback Speech Messages
*7??#
? = 1 to 15
Record Speech Messages
*8??#
? = 1 to 15
Turn Remote Control Outputs On or Off
*9?#
? = 1 to 5
Play main menu
*#
End Call
*99#
Remote Access
To gain remote access to your alarm system, please proceed as follows:
1.
From any touch-tone telephone, first dial the number of your premises. If your premises
have more than one line, be sure to call the number of the line on which your
EC-P50
control panel has been installed. After a single ring, hang up, wait 10 seconds, and call
again. On the second call, the system will answer after one or two rings and announce:
“Enter passcode.”
2.
Enter your normal access code within 5 seconds or the system will attempt to answer
the call in modem mode (you will hear a high pitched tone). The system will then
prompt the current status:
“System Disarmed”
or
“System Armed”
or
“System Stay Armed”
3.
The main menu is prompted:
“Press 1 to away arm, press 2 to stay arm, press * to hear again.”
4.
Enter the function command (see remote control menu).
5.
To end the remote access session, enter
*99#
on your touch-tone phone.