background image

4

Eclipse AirHeat Burner, V2,  Design Guide 135, 6/16/2010

Introduction

Product Description

Eclipse AirHeat Burners are line type burners ideal for
generating large volumes of clean, hot air. Applications
include ovens, dryers, fume incinerators, and similar
industrial equipment. Burners are constructed of
aluminum burner bodies and diverging stainless steel air
wings. The burner bodies supply fuel to the center of the
air wings. The air and fuel mixture inside the burner is
controlled to optimize emissions and efficiency.

AirHeat Burners are assembled from straight sections
allowing for customized inputs. An integral combustion air
blower can be ordered mounted on the back of the
burner’s steel or stainless steel housing case. By
supplying the correct air volume and pressure to the
burner, the blower allows stable operation over a wide
range of duct velocities without installing a profile plate
around the burner.

Brackets are available for slot firing or duct mounting and
flanges are available for continuous flange mounting.
Right hand or left hand gas piping can be supplied with
BSP or NPT connections. A reduced port fuel control
valve can be supplied with a variety of control motor and
linkage options. Ignition can be by direct spark or by spark
ignited pilot. Flame rod flame supervision can be from
either or both ends. Several air flow switches are also
available factory mounted on the burner.

Figure 1.1. AirHeat Burner

Audience

This manual has been written for personnel already
familiar with all aspects of a gas burner and it’s add-on
components, also referred to as the burner package.

These aspects are:

• Design / Selection

• Use

• Maintenance

• Safety

The audience is expected to be qualified and have
experience with this type of equipment and its working
environment.

Purpose

The purpose of this manual is to make sure that the design
of a safe, effective and trouble-free system is carried out.

AirHeat Documents

Design Guide No. 135

• This document

Datasheet Series No. 135

•  Available for individual AirHeat models

•  Required to complete installation

Installation Guide No. 135

•  Used with Datasheet to complete installationn

Related Documents

•  EFE 825 (Combustion Engineering Guide)

•  Eclipse Bulletins and Information Guides: 710, 720, 

732, 742, 760, 818, 832, 852, 854, 856, 610, 620, 
630, 826, 820, 930, I-354

Burner with blower

Burner less blower

with inlet g

a

s piping

a

nd fuel 

c

ontrol 

va

l

v

e

a

nd 

c

ontinuous

m

ounting fl

a

nges

Burner less blower

with inlet g

a

s piping

a

nd fuel 

c

ontrol 

va

l

v

e

a

nd sp

a

rk ignited pilot.

1

Summary of Contents for AirHeat AH series

Page 1: ...Eclipse AirHeat Burner AH Serie 135 Design Guide 6 16 2010 Version 2...

Page 2: ...It must be understood that Eclipse s liability for its product whether due to breach of warranty negligence strict liability or otherwise is limited to the furnishing of replacement parts and Eclipse...

Page 3: ...ty 5 Safety Warnings 5 Capabilities 5 Operator Training 5 Replacement Parts 5 3 System Design 6 Design 6 Step 1 Burner Option Selection 6 Step 2 Blower Option Selection 7 Step 3 Control Methodology 8...

Page 4: ...supplied with a variety of control motor and linkage options Ignition can be by direct spark or by spark ignited pilot Flame rod flame supervision can be from either or both ends Several air flow swi...

Page 5: ...and duct sections are likely to have HOT surfaces Always wear protective clothing when approaching the burner This manual provides information in the use of the burner for its specific design purpose...

Page 6: ...lt EFE 825 Eclipse Combustion Engineering Guide or contact Eclipse Combustion if you have special conditions or questions Burner Model Size Selection Consider the following when selecting the burner s...

Page 7: ...unt to the burner Burners can be ordered with control motor bracket and mounting hardware only Customer supplied control motors must conform to the these specifications rotation not to exceed 2 rpm mi...

Page 8: ...Control Methodology Input is normally controled by a motorized butterfly valve in the gas line to the burner A control signal is sent from a process temperature controller sold separately to the cont...

Page 9: ...ith the burner and includes an adjustable flow gas cock and pressure regulator It is not possible to use a continuous or intermittent pilot The pilot fuel flow should be interrupted after the trial ig...

Page 10: ...mplies with all local safety standards and codes set by the authorities within that jurisdiction Contact Eclipse for further information NOTE Eclipse supports NFPA regulations two gas shut off valves...

Page 11: ...mm inch in 3 94 x 10 2 MJ Nm BTU ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From T...

Page 12: ...n both sides of the main gas shut off valve train 710 Solenoid Shut Off Valve Normally Closed Solenoid valves are used to automatically shut off the gas supply on a bypass gas system or on small capac...

Page 13: ...iii Eclipse AirHeat Burner V2 Design Guide 135 6 16 2010 Notes...

Page 14: ...Offered By Power Equipment Company 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3800 Fax 804 236 3882 www peconet com...