Eclipse RatioAir v1 - Installation Guide No. 115, 4/7/06
1
i
NstallatioN
(
CoNtiNueD
)
4
2
Chamber
insulation
1
Chamber Wall
Make sure the chamber wall
is strong enough to support
the weight of the burner
. If necessary, reinforce the
mounting area.
Burner Mounting
Mount burner to chamber wall using four (4) customer supplied
nuts and lock washers.
Alloy Combustor
1.
Make sure the gasket is installed between
the burner and the chamber wall .
2.
Make sure that gasket does not leak.
3.
Check the size of the clearance. If the gap
around the firing tube is larger than 1/2”, pack the
gap with ceramic fiber .
Silicon Carbide (SiC) Combustor only
1.
Make sure the gasket is installed between the
burner flange and chamber wall.
2.
Make sure that gasket is installed between SiC tube
and flange .
3.
Make sure neither gasket nor
leaks.
4.
Check the size of the clearance. If the gap
around the firing tube is larger than 1/2”, pack the gap
with ceramic fiber .
1
2
1
3
4
1
2
5
6
5
1
4
3
Alloy
1
2
4
6
5
Silicon Carbide