background image

 

 

 

 

WPNET wall panel series: 
WPNET4KV – WPNET8K -WPNETEX 

REMOTE CONTROLERS AND INTERFACES 

Digital wall control 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

Summary of Contents for WPNET Series

Page 1: ...WPNET wall panel series WPNET4KV WPNET8K WPNETEX REMOTE CONTROLERS AND INTERFACES Digital wall control USER MANUAL ...

Page 2: ...on surface or flush 7 5 3 Installing an External Power Supply 8 6 UNIT MANAGEMENT in standard or individual mode 9 6 1 Unit WPNET4KV management 9 6 2 Unit WPNET8K management 13 6 3 Unit WPNET12KV management 16 6 4 Unit WPNETEX management 17 6 4 1 Preset selection 19 6 4 2 Selecting Sources 21 6 4 3 Equalization settings 23 6 4 4 Volume setting MUTE 24 6 5 Units WPNET4KV or WPNET12KV operation in M...

Page 3: ...3 10 BLOCK DIAGRAM 33 10 1 WPNET4KV EX 33 10 2 WPNET8K 33 11 TECHNICAL FEATURES 34 11 1 WPNET4KV EX 34 11 2 WPNET8K 34 12 ASSEMBLY DIAGRAM 35 13 PACKAGE CONTENTS 36 ...

Page 4: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Page 5: ... any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains switching off the POWER switch all the functions and light indicators of the amplifier will be stopped but fully disconnecting the device from mains is don...

Page 6: ... Manager Application manual for more information The EclerNet Manager application is available for download at www ecler com They allow remote control functions over MIMO4040DN such as audio source selection volume adjustment preset selection etc 4 1 Main features Single European electrical box format compatible with flush and surface installation surface box supplied as standard Power over Ethern...

Page 7: ...ntrols for programming purposes and remote control possibilities model WPNET12KV A double WPa2FMBOX box is required to flush both devices together or a double WPa2SMBOX box for surface mounting Both the WPa2FMBOX and WPa2SMBOX are sold separately 5 2 Installation of a pair of adjacent WPNET4KV and WPNET8K panels on surface or flush 1 Remove frames and front panel covers from both devices WPNET4KV ...

Page 8: ...n diagram WPNET12KV rear view of printed circuit boards 5 3 Installing an External Power Supply In case of not having a PoE type power received in the control panel directly from the connection port of the network switch to which it is connected it is possible to power the panel through an optional external power supply model WP PSU External power supply connection rear view of the printed circuit...

Page 9: ...rogrammed from the EclerNet Manager application Selecting sources or presets from a preset list in the EclerNet project Adjusting the volume of a preset signal in the EclerNet project MUTE ON OFF of the same previous signal preset in the EclerNet project Front panel controls on screen information In the previous image on the front panel the available physical controls are K1 to K4 keys directly as...

Page 10: ...ociated with the K4 key In the example above which uses a carousel of audio sources as selectable options we see the following information S1 option 1 currently selected shown in negative MIMO4040DN audio input labeled DUO NET Selectable actionable by pressing the key K1 S2 option 2 MIMO4040DN audio input labeled FM TUNER Selectable by pressing the K2 key S3 option 3 MIMO4040DN audio input labeled...

Page 11: ...urning a few seconds to the previous or main screen Example S1 Name label assigned to the control panel defined from the EclerNet Manager application In the example CTRL ZONE1 S2 option of the currently selected carousel In the DUO NET example S5 S6 volume value being adjusted by rotary control displayed in real time and matching the same numerical value displayed in larger characters in the lower...

Page 12: ...ol function is not enabled for the WPNET4KV unit turning or pressing the rotary control will temporarily display such a screen with the central flashing symbols The long press 5 seconds on the rotary control displays the configuration parameters of the unit name model firmware version and Ethernet network connection parameters ...

Page 13: ...ion In the previous image on the front panel the available physical controls of this panel are K1 to K8 keys directly associated with functions displayed on the screen And the information fields on screen are S1 to S8 text fields 1 to 8 Once the unit is connected to the network powered via PoE or optional external power supply and correctly configured from the EclerNet Manager application the main...

Page 14: ...reen in this case does not show all the characters of its label name in this general view since sometimes they do not fit in the space reserved for the texts In such cases a dot is added to the end of the displayed text Selectable actionable by pressing the key K1 S2 toS7 options 2 to 7 presets labelled 9dBV 15dBV 24dBV MUTE VOICE MEETING The information on the screen in some of these cases does n...

Page 15: ...ready active preset activated In the previous example pressing the K8 key activates the NEXT option displaying the following screen of available options The long press 5 seconds of any key K1 to K8 shows the configuration parameters of the unit name model firmware version and Ethernet network connection parameters ...

Page 16: ...reen information The resulting panel model WPNET12KV has the rough appearance of the previous image WPNET12KV has the following possible remote control functions on a MIMO4040DN unit programmed from the EclerNet Manager application Selecting sources or presets from a preset list in the EclerNet project Adjusting the volume of a preset signal in the EclerNet project MUTE ON OFF of the same previous...

Page 17: ...electing sound sources from a preset list in the EclerNet project Adjusting the volume of a preset signal in the EclerNet project MUTE ON OFF of the same previous signal preset in the EclerNet project Tone control equalizer of up to three bands or EQ filters 1 to 3 of an output mono or stereo of a MIMO4040DN unit pre configured in the EclerNet project As it offers more control functions of differe...

Page 18: ...r with rotary and pulsation functions And the information fields shown on the screen are S1 to S4 text fields 1 to 4 S5 Adjusted volume indicator signal level S6 textual value of the adjusted volume signal level Once the unit is connected to the network powered via PoE or optional external power supply and correctly configured from the EclerNet Manager application the main screen will display an i...

Page 19: ...ext to access the equalisation menu via K3 6 4 1 Preset selection The text field S1 shows the active preset in the example above the preset labeled START on the MIMO4040DN unit Pressing the K1 key takes you to the preset selection menu In this menu S3 displays the active preset while S2 flashes the options of the assigned carousel of available presets as you navigate through the K5 turn etc ...

Page 20: ...hown in the previous screen in the following example the preset MUTE returning to the main screen with the information of the new active preset updated in S1 A new press of K1 would give access to the preset selection menu with this new look active preset MUTE ...

Page 21: ...e above the preset labeled DUO NET on the MIMO4040DN unit From the main screen pressing the K2 key accesses the source selection menu In this menu S3 shows the selected source while S2 flashes the options of the assigned carousel of available sources as you navigate by turning K5 etc ...

Page 22: ... the previous screen in the following example the source DANTE16 returning to the main screen with the information of the new selected source updated in S1 A new press of K2 would give access to the font selection menu with this new aspect selected font DANTE16 ...

Page 23: ...ous example BAS BASS MI MID and TRE TREBLE Pressing keys K1 to K3 selects one of them so that the rotation of K5 allows its gain adjustment enhancement or attenuation Example for the MID filter after pressing K2 and rotating K5 Changes to these settings are in real time and do not require K5 to be pressed or any other action to confirm However a long press of K5 3 seconds within this menu resets t...

Page 24: ...conds to the previous or main screen Example S1 Name label assigned to the control panel defined from the EclerNet Manager application In the example EXTENDED C EXTENDED CONTROL S2 option of the currently selected source carousel In the DUO NET example S5 S6 volume value being adjusted by rotary control displayed in real time and matching the same numerical value displayed in larger characters in ...

Page 25: ...ET4KV and or WPNET12KV the MULTI type This type of panels are associated to a hardware unit WPNET4KV or WPNET12KV respectively which are programmed to take the role of different individual panels WPNET4KV or WPNET12KV included in the project These individual panels can in turn have a one to one link with real WPNET4KV or WPNET12KV hardware units or exist in the project only virtually In this way b...

Page 26: ...twist The image above shows how a control programmed as WPNET4KV MULTI is taking on the role of an individual WPNET4KV control called CTRL ZONE1 so that it shows the carousel options and the rest of the carousel information A long press on the rotary control 5 seconds gives access to the role change menu of this MULTI type hardware panel ...

Page 27: ...s panel CTRL ZONE1 From the EclerNet Manager application it is possible to define Number of individual panels included in a project Specific programming of each of the above and link or not to real panels hardware Number of panels WPNET4KV and or WPNET12KV type MULTI Programming of the same selection from the list of individual panels type WPNET4KV and WPNET12KV previously defined of which of them...

Page 28: ...s as selectable options we see the following information S1 option 1 currently selected shown in negative MIMO4040DN audio input labeled DUO NET Selectable actionable by pressing the key K1 S2 option 2 MIMO4040DN audio input labeled FM TUNER Selectable by pressing the K2 key S3 option 3 MIMO4040DN audio input labeled ePLAYER1 Selectable by pressing the K3 key S4 option 4 Move to the next screen of...

Page 29: ...ferent screen is temporarily shown returning a few seconds to the previous or main screen Example S1 Name label assigned to the control panel defined from the EclerNet Manager application In the example CTRL ZONE1 S2 option of the currently selected carousel In the DUO NET example S5 S6 volume value being adjusted by rotary control displayed in real time and matching the same numerical value displ...

Page 30: ...ol function is not enabled for the WPNET4KV unit turning or pressing the rotary control will temporarily display such a screen with the central flashing symbols The long press 5 seconds on the rotary control displays the configuration parameters of the unit name model firmware version and Ethernet network connection parameters ...

Page 31: ...n EclerNet software firmware package is always available including the latest official versions of EclerNet Manager firmware and software 8 FRONT PANEL 8 1 WPNET4K EX 8 1 WPNET8K 1 Front panel cover 2 LCD screen 3 Selection keys K1 to K4 4 Rotary encoder K5 1 Front panel cover 2 LCD screen 3 Selection keys K1 to K4 4 Selection keys K5 to K8 ...

Page 32: ...32 9 REAR PANEL 1 J102 J107 WPNET4KV and WPNET 8K panels interconection connectors 2 J104 RJ 45 Connector 3 J106 External power 24VDC connector ...

Page 33: ...33 10 BLOCK DIAGRAM 10 1 WPNET4KV EX 10 2 WPNET8K ...

Page 34: ...sions W 86mm x D 30mm x H 86mm Weight 120gr Cable Quality CAT 5e or better 11 2 WPNET8K DIGITAL CHARACTERISTICS Control keys 8 CONTROL keys Indicators LCD Display 128x128 Pixels Communication Standard Ethernet SUPPLY CHARACTERISTICS Poe Power supply PoE class 0 802 3af Poe PD compliant External Power supply 12 24VDC Maximum Power Consumption From PoE 35mA 1 6W From Ext Power 1 5W MISCELLANEOUS Con...

Page 35: ...35 12 ASSEMBLY DIAGRAM ...

Page 36: ...nit Frame for mounting on single mechanism systems Screws for fixing to surface or flush box Magnet for cover removal Surface box Quick User Guide Warranty Card Only in model WPNET8K Hoses for connection to WPNET4KV converting the pair into a panel type WPNET12KV ...

Page 37: ...e to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in design or manufacture that may affect these product specifications Motors 166 168 08038 Barcelona España 34 932238403 information ecler com www ecler com ...

Reviews: