Ecler MIM088SG User Manual Download Page 1

 

50-0317-01

07

 

MIMO88SG-1212SG 

EN 

 

 

 

MIMO88SG / 1212SG 

DIGITAL MATRIXES 

Installation Digital Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

Summary of Contents for MIM088SG

Page 1: ...50 0317 0107 MIMO88SG 1212SG EN MIMO88SG 1212SG DIGITAL MATRIXES Installation Digital Matrix USER MANUAL...

Page 2: ...Ports 10 5 8 Remote control RS 232 Port 11 5 9 Front panel controls and LED indicators 11 CLEANING 11 FUNCTION LIST 12 FUNCTION DIAGRAMS 13 8 1 MIMO88SG 13 8 2 MIMO1212SG 14 TECHNICAL CHARACTERISTICS...

Page 3: ...k of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not...

Page 4: ...stopped but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connec...

Page 5: ...owing features 8 MIMO88SG or 12 MIMO1212SG balanced MIC LINE inputs independent phantom power per input channel 8 MIMO88SG or 12 MIMO1212SG balanced LINE outputs 8 MIMO88SG or 12 MIMO1212SG GPI contro...

Page 6: ...ompatible with the MIMO88SG MIMO1212SG hardware which can be freely updated with anyone of them The MIMO SG programming is done with EclerNet Manager Please refer to EclerNet Manager Software manual a...

Page 7: ...nit offers 8 MIMO88SG or 12 MIMO1212SG balanced analogue signal inputs IN accepting both line and microphone level signals Input signal type selection and management are carried out from EclerNet Mana...

Page 8: ...8 Ground Terminal For UNBALANCED connections leave the terminal unconnected...

Page 9: ...1 Factory Preset Network settings The factory default network settings for EclerNet Manager compatible devices are as follows IP 192 168 0 100 Mask 255 255 255 0 Gate 192 168 0 1 UDP Port 2210 5 6 RE...

Page 10: ...onnectors are screw terminal blocks with three contacts The wiring is as follows Positive 12 VDC Pin Variable voltage 0 12 VDC Pin Ground Pin WPaVOL connection to MIMO serial GPI ports WPaVOL SR conne...

Page 11: ...order the increased intensity level Output LED indicators indicate the presence of audio signal at the unit s output and its intensity level green amber and red indicate in this order the increased in...

Page 12: ...tor POWER 5 Signal output screw terminal OUT 6 Signal input screw terminal IN 7 RJ 45 connector ETHERNET 8 Screw terminals for digital remote control REMOTE 9 Screw assembled remote control terminals...

Page 13: ...13 FUNCTION DIAGRAMS 8 1 MIMO88SG 1 1 5 6 7 8 9 1 1 1 2 3 2 3 4 0 1...

Page 14: ...14 8 2 MIMO1212SG...

Page 15: ...tness better than 0 1dB THD Noise 1kHz 0dBV input line 0 004 THD Noise 1kHz 40dBV input mic 0 008 Output Noise floor FFT 20Hz 20kHz better than 115dB Interchannel crosstalk 20Hz 20kHz better than 90dB...

Page 16: ...om 10 ms to 1000 ms Make up gain from 0 to 10 dB Input Frequency Shifter x4 Feedback Loop Reducer Available on IN1 to IN4 ON OFF function Output Limiter x8 Bypass On Off Threshold from 36 dBV to 18 dB...

Page 17: ...rs Resolution 24bit AKM Dynamic Range AD 110dB DA 115dB Analogue 12 Input Output Terminal block Symmetrical Analogue Input headroom 27dBV 30dBu Max output level 18dBV 21dBu Input sensitivity 0dBV out...

Page 18: ...80 dB Attack time from 0 1 ms to 500 ms Hold time from 10 ms to 3000 ms Release time from 10 ms to 1000 ms Input Compressor Limiter x12 Bypass On Off Threshold from 36 dBV to 18 dBV Ratio 1 1 to inf...

Page 19: ...Weight 3 2kg Supply Mains 90 264VCA 47 63Hz Power consumption 75VA Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb Auto X Over CAT5 up to 100m Remote Bus Over twisted pairs up to 1km s...

Page 20: ...20 BLOCK DIAGRAMS 10 1 MIMO88SG...

Page 21: ...21 10 2 MIMO1212SG...

Page 22: ...22 TP NET PROTOCOL SOFTWARE Third Party NET USER MANUAL...

Page 23: ...fixed no autonegotiation for all the devices except for DUO NET PLAYER eMIMO1616 HUB series and MIMO4040CDN which use 115200 baud rate Data bits 8 Parity None Stop bits 1 Flow control None In case th...

Page 24: ...essage that is sent from the EclerNet device when the initial message from the client to the device was SYSTEM CONNECT PINGPONG The communication using UDP or RS 232 starts when a client sends the mes...

Page 25: ...vel Pre Vumeter Level y Post Vumeter Level are numerical values in the 0 100 range that define values in a scale equivalent to inf 0 dB GPI GPO are numerical values within the 1 8 range for the MIMO88...

Page 26: ...rrent device status with DATA messages DISCONNECT Cancel subscriptions and terminates communication SUBSCRIPTION_RATE Rate Alive message from device PING Alive message from device PONG Alive ACK messa...

Page 27: ...alue of an Output Channel GPI Input Gets the current value of a General Purpose Input GPO Output Gets the current value of a General Purpose Output not valid for MIMO88SG MIMO1212SG INFO_NAME Gets the...

Page 28: ...GPO Value Sets the current value for a General Purpose Output not valid for MIMO88SG VIRTUAL_CONTROL Virtual Control Value Sets the Virtual Control value Value can range from 1 to 100 INC ILEVEL Input...

Page 29: ...utput Channel VU meter UNSUBSCRIBE ALL Unsubscribe to all VU meters IVU Input Channel Unsubscribe to an Input Channel VU meter OVU Output Channel Unsubscribe to an Output Channel VU meter Note INC and...

Page 30: ...tus for a Matrix Point VIRTUAL_CONTROL Virtual Control Value Shows the Virtual Control value Value can range from 1 to 100 IVU Input Channel Pre Vumeter Level Post Vumeter Level Shows the VU meter val...

Page 31: ...current status of the AUTOMIXER function for inputs 1 to 8 SUBSCRIBE GATE Subscribes to the status of the NOISE GATE for inputs 1 to 8 AUTOMIXER Subscribes to the status of the AUTOMIXER function for...

Page 32: ...MIMO1212SG MIMO88SG CONFERENCE MIMO1212SG CONFERENCE SERIES SPECIFIC ERROR CODES ERROR ID DESCRIPTION 6 UDP_ERROR_TIMEOUT_PONG 7 UDP_ERROR_CONNECT_WHILE_CONNECTED 8 UDP_ERROR_DISCONNECT_WHILE_UNCONNE...

Page 33: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Reviews: