5.
CONNECTIONS
The connection terminals for models IC6 and IC8 are of the pressure clamp type for
bare cable. Once connected, just select the mode and working power of the unit with
a simple screwdriver. Always respect the polarity.
IC6 Connection plate
In the IC3 model, the connection terminals are screw-type terminal blocks. Connect
the cables as follows:
•
Between "0" and "8 / 10W" terminals (negative and positive, respectively) if
your amplifier is of low impedance
•
Between the "COM" terminals and "6W or 3W or 1.5W @ 100V" (negative and
positive, respectively) if your amplifier is of high impedance, thus directly
selecting a working power for the IC3 unit
The IC series are shipped from factory with the switch in 100V/70V position. If it is
connected to a low-impedance amplifier, the speaker will not be damaged, but will
perform way below its full potential. If the speaker is accidentally connected to a
100V/70V line in the 8
position, it will be severely damaged.
The installation of each unit is easily carried out using the 3 rotating tabs incorporated
in models IC6 and IC8, and spring clamps in model IC3. For more information on the
installation method, see section 5 of this manual.