TECHNICAL CHARACTERISTICS 

eUC106 

 

 

System 

 

Effective frequency range

74 Hz-20 kHz 

Coverage angle

151°x151° (HxV) 

Power handling  40 W RMS / 160 W Peak 

Sensitivity

3

  90 dB (1W/1m) 

Maximum SPL

106 dB continuous / 112 dB peak 

Power options 

100V: 32W / 16W / 8W / 4W / 8Ω

 

70V: 16W / 8W / 4W / 2W / 8Ω

 

Recommended amplifier power  80 W RMS 

Transducers 

 

Ways  2 

Low frequency driver  6,5" woofer 

High frequency driver  1" tweeter 

Nominal impedance 

8Ω

 

Physical

 

 

Connection type  Stripped wire 

Installation options  Ceiling (pendant) 

Mounting system  Cabinet 

Enclosure material  ABS 

Cable length  3m 

Finished colour  White (RAL 9003) or black (RAL 9005) 

Dimensions (ØxD)  270x215mm / 10.63"x8.46" 

Weight  3.0 kg / 6.61 lb 

 

1

10dB below the sound pressure level at specified sensitivity

 

2

6dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz.

 

3

Measured on-axis, far field and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz. 

4

Calculated from sensitivity and power handling specifications, exclusive of power compression 

 

 

Summary of Contents for eUC106

Page 1: ...50 0402 0104 eUC106 EN eUC106 LOUDSPEAKERS Spherical pendant loudspeaker USER MANUAL...

Page 2: ...2 NDICE IMPORTANT REMARK 3 IMPORTANT SAFETY INSTRUCTIONS 3 IMPORTANT NOTE 5 INTRODUCTION 5 CONNECTIONS 6 LOCATION AND INSTALLATION 7 PAINTING 10 TECHNICAL CHARACTERISTICS 11...

Page 3: ...ked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of read...

Page 4: ...witching off the POWER switch all the functions and light indicators of the unit will be stopped but fully disconnecting the device from mains is done by unplugging the power cable from the mains inpu...

Page 5: ...the best performance from this equipment To ensure optimal operation of this device we strongly recommend that its maintenance be carried out by our authorised Technical Services All ECLER products ar...

Page 6: ...g mode and power using a flat screwdriver 40 WRMS 8 32 16 8 4W 100V 16 8 4 2W 70V eUC106 is supplied with the switch in the 70V 100V position If you accidentally connect the system to a low impedance...

Page 7: ...ficiently robust to withstand the weight of the loudspeaker The supplied eye bolt is suitable for mounting on a strong wood surface If loudspeakers are mounted on other surface type use an appropriate...

Page 8: ...carabineer in the hook screw previously fixed on the ceiling Ensure that the carabiner is properly closed 4 Take the safety steel wire from loudspeaker line cable and install it in the clamp as shown...

Page 9: ...allation totally secure introduce safety cable in the eye bolt too 6 Connect the audio cables to the line coming from the amplifier and move plastic cap up to the ceiling covering the fixation element...

Page 10: ...of the aesthetic criteria of the room for which it is intended eUC106 comes in white RAL 9003 and black RAL 9005 WARNING If you are using spray paint to paint the speaker do not point it perpendicula...

Page 11: ...cal Connection type Stripped wire Installation options Ceiling pendant Mounting system Cabinet Enclosure material ABS Cable length 3m Finished colour White RAL 9003 or black RAL 9005 Dimensions xD 270...

Page 12: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Reviews: