Ecler DLA600 User Manual Download Page 2

 2

1. IMPORTANT REMARK 

We thank you for trusting in us and choosing our DLA600 adapter unit. In order to get the optimum operation 

and efficiency from this unit, it is VERY IMPORTANT - before you plug anything - to read this manual very carefully 
and bear in mind all considerations specified within it.  

We strongly recommend that its maintenance be carried out by our Authorised Technical services. 
Do not expose the unit to rain or water splashes, and do not place liquid containers or incandescent 

objects like candles on top of the unit. Do not obstruct the ventilation shafts with any kind of material. 
There are no user serviceable parts inside the unit. 

 
 
INTRODUCTION 
 

The use of a 70V / 100V loudspeaker distribution system responds to the necessity of a flexible system that 

firstly allows the simultaneous use of different types of loudspeakers with different impedances, power handlings, etc. 
and secondly minimises the power loss caused by the conductor resistance in long cable runs. 

Basically, the system uses transformers to adapt each loudspeaker to the 70V / 100V line. These line 

voltages are achieved either with high output power amplifiers (e.g. 1250 @ 8

) or with smaller power amplifiers 

followed by an output transformer. 

In order to use conventional medium-sized power amplifiers in 70V /100V lines (e.g. hotels, factories, train 

stations, bus terminals, stores, supermarkets, parks, streets… ) it is required to place an intermediate unit between 
the amplifier’s output and the loudspeaker line. The DLA600 fulfils this task and offers exceptional flexibility thanks 
to its two independent channels for 100V and 70V outputs. 

The DLA600 intermediate unit complements ECLERs power amplifiers MPA4-80R, MPA6-80R, 

MPA4-150R, MPA4-400R and DPA600, although it’s perfectly suited for other amplifiers with similar 
characteristics. 
 
 
INSTALLATION TIPS 

As in many other systems, it’s highly recommended not to reduce the total load impedance below the 

minimum admissible impedance. The usual procedure for calculating the maximum number of loudspeakers that a 
given line can bear, is to sum the power handling of all loudspeakers and check that this sum is not bigger than the 
maximum output power of the amplifier. 

For the previous statement to be true, and to ensure a trouble-free operation of the power amplifier, 

loudspeakers should be of the highest affordable quality and be installed correctly. 

To guarantee an optimum performance of the DLA600, the output power of the amplifier should be as 

similar as possible to the selected input power on the DLA600. 

If the output power of the amplifier does not match any of the 3 options on the DLA600, connect the 

amplifier to the higher rated input on the DLA600. For example, if you have a 200W amplifier, you should connect it 
to the 300W input on the DLA600. 

Keep in mind that if these power figures do not match, the output voltage of the DLA600 will not be exactly 

100V or 70V. 

If you use a higher output power on a lower rated DLA600 input, you run the risk of saturating the 

transformer and poor system performance. 

Always refer to the indications printed on the panel when connecting the inputs and outputs to the DLA600. 

These indications are reproduced at the end of this manual together with two installation examples. 

The DLA600 features lateral rack ears that allow, thanks to its standard 19’’ width (482.6 mm) and 1 unit 

height (44mm), installation in normalized rack furniture. 
 
 
CLEANING 
 

The front panel should not be cleaned with dissolvent or abrasive substances because silk-printing could be 

damaged. To clean it, use a soft cloth slightly wet with water and neutral liquid soap; dry it with a clean cloth. Be 
careful that water never gets into the unit through the holes of the unit. 
 
 
 
 
 
 
 
 
 
 

All numbers subject to variation due to production tolerances. ECLER SA reserves the right to make changes or 
improvements in manufacturing or design which may affect specifications. 

Summary of Contents for DLA600

Page 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D UTILISATION BEDIENUNGSANLEITUNG ...

Page 2: ...r systems it s highly recommended not to reduce the total load impedance below the minimum admissible impedance The usual procedure for calculating the maximum number of loudspeakers that a given line can bear is to sum the power handling of all loudspeakers and check that this sum is not bigger than the maximum output power of the amplifier For the previous statement to be true and to ensure a tr...

Page 3: ...rísticas similares RECOMENDACIONES DE INSTALACIÓN Es importante como en cualquier otro sistema no bajar la impedancia de la carga por debajo de la impedancia mínima admisible La manera usual de calcular el número máximo de altavoces que permite cada línea es sumar las potencias de cada altavoz y que la suma no supere la potencia máxima del amplificador Para que se cumpla el principio anterior y el...

Page 4: ...ALLATION Il est important comme pour tout autre système de ne pas réduire l impédance de la charge en deçà du seuil minimal admissible Pour calculer le nombre maximum de haut parleurs autorisés sur chaque ligne on additionne généralement les puissances de chaque haut parleur et l on s assure que la somme obtenue ne dépasse pas la puissance maximale de l amplificateur Pour que la condition ci dessu...

Page 5: ...IE INSTALLATION Wie in vielen anderen Systemen ist es sehr wichtig das die installierte Gesamtimpedanz einen höheren Wert als die von der Endstufe akzeptierte Mindest Lastimpedanz hat Die gewöhnliche Methode um die maximale Anzahl anschließbarer Lautsprecher zu berechnen besteht darin die Nennleistung aller Lautsprecher zu addieren und sicherzustellen daß diese Summe niedriger ist als die maximale...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...se 3dB 20Hz 30kHz Dimensions 482 6x266 5x44 Weight 12kg ECLER Laboratorio de electro acústica S A Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com e mail info ecler es 50 0076 01 03 WIRING DIAGRAM ONE CHANNEL 0V 100V 70V 300W 150W 80W AMPLIFIER OUTPUT MAX RMS AMPLIFIER OUTPUT POWER 4 OHM CHANNEL 2 80W 150W INPUT 300W 70V OUTPUT 100V 0V CHANNEL 1 OUTPUT 100V 0V 70V 150W INPUT 300W 8...

Reviews: