64
TYP
E
PARAM1
PARAM2
PARAM3
PARAM4
DESCRIPCIÓN
SET
AUTOLOAD_PRESET1
ON/OFF
Sets the current AUTOLOAD_PRESET1 at Startup function
PRESET_NUMBER
<Preset=P1:P20>
<Preset=T1:T9>
Sets (loads) the current PRESET number
LOAD_PRESET
<Preset=P1:P20>
<Preset=T1:T9>
Sets (loads) the current PRESET number (same function as
PRESET_NUMBER)
SAVE_PRESET
<Preset=P1:P20>
“<Name>”
Saves the current configuration into a certain PRESET position (from
P1 to P20) and with a certain LABEL, or name (between quotation
marks to allow for blank characters in the label)
REMOTE_MODE
<Remote=R1:R4> <RemoteMode>
Sets the working mode for a certain REMOTE port (from R1 to R4).
Valid working modes are: DISABLED, IN_VOL, ZONE_VOL, IN_SEL,
IN_SEL_IN_LEVEL, IN_SEL_ZONE_VOL, PRESET, PRESET_ZONE_VOL
REMOTE_INPUTS
<Remote=R1:R4> <Inputs=I1:I6>
Sets the list of inputs affected by the working mode of a certain
REMOTE port (from R1 to R4). Inputs parameter can include I1 to I6,
separated by comma characters and no blank space (example: I1,I2,I3)
REMOTE_ZONES
<Remote=R1:R4> <Zones=ZA:ZD>
Sets the list of outputs affected by the working mode of a certain
REMOTE port (from R1 to R4). Zones parameter can include ZA to ZD,
separated by comma characters and no blank space (example:
ZA,ZC,ZD)
DISPLAY_MODE
<DisplayMode>
Sets the current LCD DISPLAY MODE (NORMAL or DIMMED or OFF)
LCD_CONTRAST
<Contrast=0:100
>
Sets the current LCD DISPLAY CONTRAST level
EXT_MUTE_ZONES
<Zones=ZA:ZD>
Sets the list of outputs to be muted by an external contact closure,
connected to the MUTE port. Zones parameter can include ZA to ZD,
separated by comma characters and no blank space (example:
ZA,ZC,ZD)
IN_LABEL
<Input=I1:I6>
“<Label>”
Sets the current LABEL (name) for the specified INPUT (between
quotation marks to allow for blank characters in the label)
IN_STEREO
<Input=I3:I6>
ON/OFF
Sets the current STEREO link status (ON or OFF) for INPUTs 4 and 5