connect the alarm cable in the pump on NO and on C. The alarm contact
must be used to cut off refrigeration in case of an overflow in the detection
unit.
Ensure that the electrical connections to the pump are sealed fully using
the insulating cap, which should be secured with a cable tie.
Hydraulic connection :
On mini-split, wall mounted equipment, the detection unit is connected to the
end of evacuation pipe by means of a rubber sleeve (supplied). On other
types, the rubber sleeve is connected to the drain tank outlet. The length of
this sleeve can be adjusted. The detection unit must be installed horizontally,
in the location reserved inside the foam elbow (tolerance 15°). It must not be
fixed on a metallic brace, to avoid dysfunction of the magnet. Install the
ventilation tube on the detection block.
The hydraulic discharge connection uses flexible piping having an inside Ø6
mm.
The
EE 1200
must not be immersed or placed outside of the premises or in a
damp place, or in temperature below 0°C.
Tubing
Detection unit
Ventilation tubing