background image

Echoflex Installation Guide

Ceiling Vacancy-Occupancy Sensor

Lens Masking

Peel and stick lens mask

Lens mask stickers are provided to block a

section of the lens from detecting
occupancy. To attach, remove the backing
and stick the mask on the sensor lens to
cover the target section. Cut to size, if
required.

Link to a Controller

The target controller must be installed,
powered, and within range of the RVS RCS.
Repeating the linking process can also be used to unlink the device.

 

Teach button

Battery holder

1. Remove the cover to access the

[Teach]

button, using your fingers

to flex it gently and release the
tabs that hold it in place. If you
have difficulty, consider inserting a
small flatblade screwdriver under a
release tab.

2. Press the

[Learn]

button on the

controller to activate Link mode. If
necessary, refer to the controller product documentation.

3. Press the

[Teach]

button on the RVS RCS once to send a message. An

LED blinks to confirm a successful transmission.

4. Deactivate Link mode on the controller before attempting to link to

any other controllers.

Battery Power

A CR1632 battery is not required for normal operation of RVS models if
the sensor receives adequate natural or artificial light. See the table in the

Light Level Test on the next page

. A battery may be required to run

installation tests or when the artificial light is insufficient to power the
sensor.

A CR1632 is included with RCS models. The battery may be factory
installed or packed separately according to shipping regulations. Insert
the battery if required or remove the protective plastic tab before
installing the RVS RCS.

Note:

When the sensor transmits a message, the LED blinks. The

LED color indicates the battery's strength: green if good, blue if
low, and red if dead or missing.

Ceiling Vacancy-Occupancy Sensor

Page 5 of 12

Echoflex

Summary of Contents for RVS-A-xW Series

Page 1: ...es The vacancy ceiling sensor RVS has two solar cells to harvest energy when the lights are ON while the occupancy ceiling sensor RCS is battery powered to support auto ON occupancy sensor application...

Page 2: ...to block off specific areas See Lens Masking on page 5 Do not install within 2 5 m 8 ft of an HVAC airflow duct or vent For the solar powered RVS model before linking the sensor expose it to a good li...

Page 3: ...uble sided Tape or Velcro 1 Cut two lengths of tape not provided to the appropriate size and adhere one side to the mounting plate and the other to the ceiling 2 Press the sensor firmly in place Sensi...

Page 4: ...upancy Timer and the controller s Occupancy Timer When the space is vacant and all timers have expired only PIR detection or manual control can change the state to occupied if the sensor is configured...

Page 5: ...fer to the controller product documentation 3 Press the Teach button on the RVS RCS once to send a message An LED blinks to confirm a successful transmission 4 Deactivate Link mode on the controller b...

Page 6: ...ructions Light Level Test green LED Range Confirmation blue LED Walk Test red LED Sensor Setting red and blue LEDs LED Display green and red LEDs The menu times out after two minutes of inactivity Lig...

Page 7: ...inked controllers detected The test repeats every five seconds and runs for 50 seconds To exit before the time out press and hold the Teach button Walk Test The Walk Test verifies the boundaries or li...

Page 8: ...nks Occupancy Timer DT model only Note Echoflex dual tech sensors have a configurable Occupancy Timer that sends a vacancy message when expired If using another controller brand with a DT model you ma...

Page 9: ...when the green and red LEDs are both blinking 3 Press and hold the Teach button until the LEDs stop blinking to select LED Display 4 Press the Teach button to toggle between the two states Red LED bli...

Page 10: ...io communications Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to operate the product Operation of this equipm...

Page 11: ...Echoflex Installation Guide Ceiling Vacancy Occupancy Sensor Ceiling Vacancy Occupancy Sensor Page 11 of 12 Echoflex...

Page 12: ...Echoflex Installation Guide Ceiling Vacancy Occupancy Sensor Ceiling Vacancy Occupancy Sensor Page 12 of 12 Echoflex...

Reviews: