When using Category 5 (or equivalent) cable on the EchoConnect

communication bus, please note the following:

Cat5 wiring must be terminated using EchoConnect Cat5
Termination Kit and must be installed using a bus topology.
Refer to the installation guide that is provided with the Cat5
Termination Kit (8186A1207) for information to terminate
Cat5 wiring.

Not all topologies are supported using Cat5; careful planning
is required to ensure the proper termination kits are available
and the wire is pulled appropriately.

Install the Interface

Receptacle spacers are
provided to help align the
Interface and cover flush
against the wall in flush
mount application. The
spacers are not required
when installing the
Interface in a surface
mounted box.

1.

Insert the Interface electronics and wiring into the back box. To install
multiple Elaho products (multi-gang), insert the Interface electronics
into the back box from the right to the left side for the best alignment
and fit. The alignment bracket will slightly overlap the Interface to the
right when properly installed.

a.

Use spacers as needed to provide a flush mounted Interface.

b.

Fold the spacer in a zig-zag fashion and press the stack together
to achieve the thickness needed to fill the gap between the
Interface, wall surface, and the back box.

c.

Cut off and discard the excess.

d.

Place the stack between the Interface electronics and the flush
mounted back box.

2.

Secure each Interface electronics in place using the two screws
provided. If using spacers, insert the screws through the spacers as
well.

ElahoAccess Interface Installation Guide

Page 5 of 8

Echoflex Solutions, Inc.

Summary of Contents for ElahoAccess Interface

Page 1: ...and devices Prepare for installation wall plate alignment bracket interface Included in shipment The ElahoAccess Interface ships with interface assembly decorator style wall plate 24 VDC power pigtail...

Page 2: ...t uses one pair of wires data and data Echoflex recommends using Belden 8471 or approved equal Class 2 wire The total combined length of an EchoConnect wire run using Belden 8471 or equal may not exce...

Page 3: ...ll national and local codes for electrical equipment Note NEC Class 2 product to be wired in accordance to NEC Article 725 and local jurisdiction requirements Install the back box plumb and square for...

Page 4: ...res and the installed Belden 8471 control wires One WAGO should be used for the white wire pair data and one for the black wire pair data Open the terminal levers on the WAGO connector and insert the...

Page 5: ...d when installing the Interface in a surface mounted box 1 Insert the Interface electronics and wiring into the back box To install multiple Elaho products multi gang insert the Interface electronics...

Page 6: ...ate is secured to the Interface with magnets that are assembled to the wall plate 1 Align the top of the wall plate to the Interface and angle the bottom approximately 20 degrees 2 Hook the top of the...

Page 7: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee t...

Page 8: ...Echoflex Installation Guide ElahoAccess Interface ElahoAccess Interface Installation Guide Page 8 of 8 Echoflex Solutions Inc...

Reviews: