DPAS-2100
99922238047
48
© 12/2022 ECHO Incorporated
TROUBLE SHOOTING
TROUBLE SHOOTING
Problem
Possible Cause
Solution
The machine
does not
start when
you push
the power
switch.
No electrical contact
between the machine
and the battery.
1. Remove battery.
2. Check contact and install the battery
again.
The battery is depleted. Charge the battery.
The lock-off lever switch
and power switch are
not pushed at the same
time.
1. Push the lock-off lever switch and
hold it.
2. Pull the power switch to start the
machine.
The machine
stops when
you cut.
The battery or machine
is too hot.
1. Cool the battery until its func-tion
returns to normal.
2. Cool the machine for approximately
10 minutes.
The battery is
disconnected from the
tool.
Install the battery again.
The battery is depleted. Charge the battery.
Red Charger
light flashes
or does not
light up.
Plug not connected to
power outlet.
Plug in charger.
Battery pack not
installed properly.
Check the battery installation.
Obstructed connection. Reinstall battery after removing
obstructions.
Fault in the charger.
Consult your dealer.
Fault in the battery
pack.
Consult your dealer.
Unit will not
turn on
Battery pack not
installed properly.
Check battery installation.
Unit does
not run when
turned on
Battery pack
discharged.
Charge battery.
Battery pack outside
acceptable temperature
range.
Remove the battery and allow to cool.
Running time
is too short.
Battery pack outside
acceptable temperature
range.
Remove battery and allow to cool.
Unit electronics too hot. Turn unit off and allow to cool.
Battery pack
discharged.
Charge the battery.