26
2.
Place the stop switch in the "OFF" position.
3.
Remove accumulation of grease, oil, dirt and debris
from exterior of unit.
4.
Perform all periodic lubrication and services that are
required.
5.
Tighten all the screws and nuts.
6.
Drain the fuel tank completely and pull the recoil
starter handle several times to remove fuel from the
carburetor.
S
TORAGE
Long Term Storage (over 30 days)
WARNING
DANGER
During operation the muffler or catalytic muffler and surrounding cover become hot. Always keep exhaust area clear
of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may
result.
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte-
nance which includes the following:
1.
Store unit in a dry, dust free place, out of the reach of children.
WARNING
DANGER
Do not store in enclosure where fuel fumes may accumulate or reach an open flame or spark.
7.
Remove the spark plug and pour 7 cc (1/4 oz.) (1/2
tablespoon) of fresh, clean, two-stroke engine oil into
the cylinder through the spark plug hole.
A. Place a clean cloth over the spark plug hole.
B. Pull the recoil starter handle 2-3 times to distribute
the oil inside the engine.
8.
Install the spark plug (do not connect spark plug
cable).
IMPORTANT
Do not store the unit with tension remaining on the
starter spring.