![Eccotemp i12 Series Use And Care Manual Download Page 23](http://html1.mh-extra.com/html/eccotemp/i12-series/i12-series_use-and-care-manual_3912507023.webp)
English
Installation
POWER CORD:
• The electric power supply requirement for this water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin power supply cord. Use only a power outlet with a ground
terminal.
• The installation of an electric leakage breaker is recommended. (GFCI)
•
Keep any excess of the power supply cord on the outside of the water heater.
WARNING: Field wiring connections and electrical grounding must comply with local codes,
or in the absence of local codes, with the latest edition of the National Electrical Code,ANSI/
NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1Part1.
WARNING: Shock hazard line voltage is present. Before servicing the water heater, turn off the
electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so could
result in severe personal injury or death.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify correct operation after servicing.
Electrical Wiring Diagram
Electrical Connection
Venting
Continued...