Ecco ED3801 Installation And Operation Instruction Download Page 3

Page 3 of 5

Flash Patterns:

Phase Operation:

Phase 1 (Ph1) flashes simultaneously with Ph1

Phase 2 (Ph2) flashes simultaneously with Ph2

Ph1 alternates with Ph2

(Up to 8 units can be Synchronized)

Apply BLUE TO BLACK wire:

-Less than 1 sec. for next pattern

-Between 1-3 sec for previous pattern

-Between 3-5 sec. for factory default pattern

-More than 5 sec. for pattern 12 (ED3802XX, ED3802XXX) and pattern 13 (ED3801X)

PATTERN 

Flash 

sim. Phase1 

sim. Phase2 

Alt. 

Single Flash 75FPM 

S1,C 

S1,C 

N/A 

Single Flash 120FPM 

S1,E1 

S1,E1 

N/A 

Double Flash 75FPM 

S1 

S1 

N/A 

Double Flash 120FPM 

S1,E1 

S1,E1 

N/A 

Quad Flash 75FPM 

R/B/A for S1,W for S2  R/B/A for S1,W for S2  N/A 

Quad Flash 150FPM 

R/B/A for S1,W for S2  R/B/A for S1,W for S2 

N/A 

Triple 75FPM 

S1 

S1 

N/A 

Quint Flash 150FPM 

R/B/A for S1,W for S2  R/B/A for S1,W for S2 

N/A 

Steady - Single 

N/A 

 

 

10 

Steady Burn 

N/A 

 

 

11 

Modulation 

N/A 

 

 

12 

2 Double Flash,2 Triple Alt. 

N/A 

 

 

13 

4 Single Flash ,2 Quad Flash Alt. 

N/A 

 

 

 

ED3801X Flash Pattern Chart

ED3802XXX Flash Pattern Chart 

 

 

PATTERN 

GROUP 

Group 1(Red line) 

 

 

 

FLASH PATTERN 

 

 

 

SYNC. 

 

 

 

COMPLIES WITH 

Group 2(White line) 

Group 3(Red & White line) 

Mode1 

Color1 

Mode2 

Color2 

Mode3 

Color3 

Mode4 

Color 

1 & 2 

Mode5 

Color 

1 & 3 

Mode6 

Color 

2 & 3 

Mode7 

Color 

1&2&3 

1-Default  1-Default  1-Default  1-Default  1-Default  1-Default  1-Default  Single 75FPM Ph1 

yes 

R/B for S1-A/W for S2 

Single 75FPM Ph2 

yes 

R/B for S1-A/W for S2 

Single 120FPM Ph1 

yes 

R/B/A for S1-W for S2,E1 

Single 120FPM Ph2 

yes 

R/B/A for S1-W for S2,E1 

Single 375FPM Ph1 

yes 

 

Single 375FPM Ph2 

yes 

 

Double 75FPM Ph1 

yes 

R/B/A for S1-W for S2 

Double 75FPM Ph2 

yes 

R/B/A for S1-W for S2 

Double 120FPM Ph1 

yes 

R/B for S1-A/W for S2,E1 

10 

10 

10 

10 

10 

10 

10 

Double 120FPM Ph2 

yes 

R/B for S1-A/W for S2,E1 

11 

11 

11 

11 

11 

11 

11 

Triple 75FPM Ph1 

yes 

R/B/A for S1-W for S2,R/B for C 

12 

12 

12 

12 

12 

12 

12 

Triple 75FPM Ph2 

yes 

R/B/A for S1-W for S2,R/B for C 

13 

13 

13 

13 

13 

13 

13 

Quad 75FPM Ph1 

yes 

R/B for S1-A/W for S2 

14 

14 

14 

14 

14 

14 

14 

Quad 75FPM Ph2 

yes 

R/B for S1-A/W for S2 

15 

15 

15 

15 

15 

15 

15 

Quad 150FPM Ph1 

yes 

R/B for S1-A/W for S2,E1 

16 

16 

16 

16 

16 

16 

16 

Quad 150FPM Ph2 

yes 

R/B for S1-A/W for S2,E1 

17 

17 

17 

 

 

 

 

CA T13 Single Flash 75FPM 

no 

S,R/B for C 

10 

18 

18 

18 

 

 

 

 

CA T13 Double Flash 75FPM 

no 

S,R/B for C 

11 

19 

19 

19 

 

 

 

 

NFPA-Quad Flash 75FPM 

no 

S,R/B for C 

12 

20 

20 

20 

 

 

 

 

ModuFlash sim. 

no 

 

13 

21 

21 

21 

 

 

 

 

2 Double Flash,2 Quad Flash 

no 

 

14 

22 

22 

22 

 

 

 

 

4 Single Flash ,2 Triple Flash 

no 

 

15 

23 

23 

23 

 

 

 

 

Autorun 

no 

 

16 

24 

24 

24 

 

 

 

 

steady burn 

no 

 

 

Reviews: