Specifications:

 

Size: 

 

EB7930: 6.0” dia. x 4.8” high

 

 

EB7935: 6.0” dia. x 6.8” high

Weight:   

approx. 3 lbs.

Input Voltage:   12-48 VDC system

 

Input Current:  

 

1.3A @ 12.8 VDC 

 

Maximum power consumption:  16 Watts

  

Temp. Range: 

-30°C to +50°C

Installation & Mounting:

Carefully remove the beacon and place it on a flat surface. Examine 

the unit for transit damage, and locate all parts. If damage is found, 

or parts are missing, contact the transit company or ECCO. Do not 

use damaged or broken parts.

Permanent Mounting:

Select the desired location on a flat surface for the LED beacon to be 

mounted. The visibility of the flash and ease of wiring access should 

be taken into consideration in the selection of the mounting location. 

1.  Using the base gasket as a template, mark the three mounting 

hole locations (see Figure 1). 

2.  Drill the holes using a 7/32”  drill size. 

3.  A fourth hole may be drilled for wire access as shown in Figure 

1, or the wires may be routed through the slot in the base for 

external access. 

4.  Connect the power wires as shown in the wiring section (see 

Figure 2).

5.  Mount the beacon with #10 hardware. 

Pipe Mounting:  

The EB7930 & EB7935 series base comes with 1” NPT threads for 

pipe mounting. 

Figure 1

920-0338-00   Rev. D

Page 2 of 4

Important!   

This unit is a safety device, and it must be

connected to its own seperate, fused power point to as

-

sure its continued operation should any other electrical 

accessory fail.

!

  

WARNING!

 Failure to follow these instructions can result in fire or injury from excessive heat build up.

 

 Operator is responsible for ensuring cigarette adapter fits correctly into cigarette/auxillary outlet used.

 For proper operation, verify cigarette/auxillary outlet circuit is rated to supply, a minimum of 10 amps. (See specifications 

 section for rated current in amperes).

 Do not exceed the current rating for the cigarette lighter power outlet recommended by vehicle manufacturer.

 Keep cigarette lighter adapter, and outlet, clean and free of debris.

 Do not use the cigarette lighter adapter when wet.

 Insert cigarette lighter adapter fully into the outlet for proper connection.

 Grasp cigarette lighter adapter, NOT cord, to remove from outlet.

 Remove cigarette lighter adapter completely from outlet when light is not in use.

Summary of Contents for EB7930 Series

Page 1: ...controls are placed within convenient reach of the operator so that s he can operate the system without losing eye contact with the roadway 5 It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly In use the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components i e open trunks or comp...

Page 2: ... through the slot in the base for external access 4 Connect the power wires as shown in the wiring section see Figure 2 5 Mount the beacon with 10 hardware Pipe Mounting The EB7930 EB7935 series base comes with 1 NPT threads for pipe mounting Figure 1 920 0338 00 Rev D Page 2 of 4 Important This unit is a safety device and it must be connected to its own seperate fused power point to as sure its c...

Page 3: ... in hot environments or operated close to their capacity Figure 2 Maintenance This LED beacon has been designed for trouble free operation There are no periodic maintenance needs for this model Troubleshooting 1 Most beacon failures including intermittent or erratic operation as well as failure of operation can be traced to wiring or battery problems Check all wiring connections fuse switch and ba...

Page 4: ...THER WARRANTIES EXPRESS OR IMPLIED THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT BUYER S SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE THE REPLACEMENT OR REPAIR OF THE PRODUCT AS DESCRIBED ABOVE Limitation of Liability IN TH...

Page 5: ...del sistema sea óptimo y que los controles queden dentro del alcance conveniente del operador de modo que pueda operar el sistema sin perder de vista el camino 5 Es responsabilidad del operador del vehículo asegurar que durante el uso todas las características del producto funcionen correctamente En uso el operador del vehículo debe garantizar que la proyección de la señal de advertencia no quede ...

Page 6: ...on herrajes n 10 UBICACIÓN DEL ORIFICIO DE MONTAJE EXTERIOR SI ASÍ LO DESEA PERFORE UN ORIFICIO EN EL CENTRO PARA ACCEDER AL CABLE DEBAJO DE LA BALIZA JUNTA DE LA BASE SUPERFICIE DE MONTAJE Montaje del tubo La base de las series EB7930 y EB7935 tiene roscas de 1 NPT para realizar el montaje del tubo Figura 1 920 0338 00 Rev D Página 2 de 4 Importante Esta unidad es un dispositivo de seguridad y de...

Page 7: ...o si se opera en forma cercana a su capacidad Figura 2 Mantenimiento Esta baliza LED ha sido diseñada para funcionamiento libre de mantenimiento No existe necesidad de efectuar un mantenimiento periódico en este modelo Localización de fallas 1 Lamayoríadelosfallosdelabaliza queincluyenelfuncionamiento intermitente o errático pueden atribuirse a problemas en el cableado o en la batería Compruebe to...

Page 8: ...ÍA EXPRESA O IMPLÍCITA MEDIANTE LA PRESENTE SE EXCLUYEN LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD O APTITUD PARA UN PROPÓSITO EN PARTICULAR QUE NO SE APLICARÁN AL PRODUCTO EL ÚNICO Y EXCLUSIVO REMEDIO DEL COMPRADOR CON RESPECTO AL CONTRATO DERECHOS POR DAÑOS O CUALQUIER OTRA TEORÍA CONTRA EL FABRICANTE RELACIONADA CON EL PRODUCTO Y SU USO SERÁ LA REPARACIÓN O EL REEMPLAZO DEL PRODUCTO SEGÚN SE D...

Page 9: ...isées et que les contrôles soient à portée de main du conducteur pour lui permettre d utiliser le système sans quitter des yeux la zone de travail 5 Pendant l utilisation il incombe au conducteur du véhicule de s assurer que toutes les fonctions de ce produit sont parfaitement opérationnelles Lors de l utilisation le conducteur du véhicule doit s assurer que la projection du signal d avertissement...

Page 10: ...n 10 EMPLACEMENT DE L ORIFICE DE MONTAGE EXTÉRIEUR SI L ALÉSAGE SOUHAITÉ SE TROUVE AU CENTRE POUR L ACCÈS DU FIL EN DESSOUS DE LA BALISE B JOINT DE BASE SURFACE DE MONTAGE Installation du tuyau La base des séries EB7930 et EB7935 est fournie avec des filetages de 1 po NPT pour l installation du tuyau Figure 1 920 0338 00 Rév D Page 2 sur 4 Important Cette unité est un dispositif de sécurité et il ...

Page 11: ...stallés dans des environnements chauds ou utilisés près de leur capacité Figure 2 Maintenance Ce phare DEL a été conçu pour une opération sans problèmes Ce modèle ne nécessite pas de maintenance périodique Dépannage 1 La plupart des défaillances de la balise y compris les fonctionnements intermittents ou irréguliers ou encore les défauts de fonctionnement peuvent être imputées à des problèmes de r...

Page 12: ...AUTRE GARANTIE EXPRESSE OU TACITE LES GARANTIES IMPLICITES DE QUALITÉ MARCHANDE OU D APTITUDE À UN USAGE PARTICULIER SONT EXCLUES ET NE S APPLIQUERONT PAS AU PRODUIT LE SEUL ET UNIQUE RECOURS DE L ACHETEUR CONTRE LE FABRICANT CONCERNANT LE PRODUIT ET SON UTILISATION QUEL QUE SOIT LE FONDEMENT DE RESPONSABILITÉ INVOQUÉ RESPONSABILITÉ CONTRACTUELLE DÉLICTUELLE OU AUTRE SERA LE REMPLACEMENT OU LA RÉP...

Reviews: