9065-0099 Rev H 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

        Installation Instructions 

1.

 

Cutout table as required (see Figure 1, Cutout Sizes & Cutout Detail) 

2.

 

Insert OASIS

TM

 into cutout from above and clamp into position using Clamps & thumb 

Screws provided.  Note: Keyslots in clamps engage over T-Studs in OASIS™ and thumb 

screws tighten against underside of table surface. (double sided tape may be required 

to prevent side of Bezel from bowing when in table). 

3.

 

Check for smooth operation of doors and adjust in cutout if required. 

4.

 

OASIS

TM

 Inserts have been installed at the factory but may be repositioned in the field if 

desired.  To reposition OASIS

TM

 Inserts remove thumb nuts & washers from rear and 

reposition as needed (see Figure 2). 

5.

 

Connect all power & data cabling as needed and check for proper operation. 

6.

 

Attach Outer Pan (optional) to underside of table as shown in Cutout Detail. 

 

 

ECA • 10 Mountain View Drive • Shelton, CT  06484 • Phone: 1-800-521-3175 • Fax: 203-924-6687 

www.electri-cable.com

 

 

CUTOUT DETAIL

9.00 Clearance

 .50 
Both 
Sides 

Cutout Width *

Door Swing 

Outer Pan 
(Optional) 

Table 

Thickness 

1.25 – 2.00 

11.20 Outer Pan Width 

    5.28 
Outer Pan 
   Depth 

Keyslots Engaged  

Over T-Studs 

Thumb 
Screws

Corded = 4.90 
Sys 42 = 5.85 