Page
2
of
3
9065-0099 Rev H
Installation Instructions
1.
Cutout table as required (see Figure 1, Cutout Sizes & Cutout Detail)
2.
Insert OASIS
TM
into cutout from above and clamp into position using Clamps & thumb
Screws provided. Note: Keyslots in clamps engage over T-Studs in OASIS™ and thumb
screws tighten against underside of table surface. (double sided tape may be required
to prevent side of Bezel from bowing when in table).
3.
Check for smooth operation of doors and adjust in cutout if required.
4.
OASIS
TM
Inserts have been installed at the factory but may be repositioned in the field if
desired. To reposition OASIS
TM
Inserts remove thumb nuts & washers from rear and
reposition as needed (see Figure 2).
5.
Connect all power & data cabling as needed and check for proper operation.
6.
Attach Outer Pan (optional) to underside of table as shown in Cutout Detail.
ECA • 10 Mountain View Drive • Shelton, CT 06484 • Phone: 1-800-521-3175 • Fax: 203-924-6687
www.electri-cable.com
CUTOUT DETAIL
9.00 Clearance
.50
Both
Sides
Cutout Width *
Door Swing
Outer Pan
(Optional)
Table
Thickness
1.25 – 2.00
11.20 Outer Pan Width
5.28
Outer Pan
Depth
Keyslots Engaged
Over T-Studs
Thumb
Screws
Corded = 4.90
Sys 42 = 5.85
Inn ovati ve Power + D ata Solutions