 Changing the default programming password code by SMS 

 

 

In order to change the “password programming code” you need to send an SMS with the following structure:  

P.1234NP.1111

 

P.1234 (the default code) required for any SMS command 
The  letters  NP  stands  for  “New  Password”  then  the  numbers  1111  are  the  new  password 
which should be used from now on in any program SMS you send to the unit. "P.1111" 
 

 

Gate Opening trigger Delay 

 

The default pulse trigger of the internal; relay is 3 seconds. In order to change the trigger opening time 
of the relay to 1 seconds (for example), send SMS with the following structure 

P.1234GOD.1,1,1,1

 

The Maximum time of the relay to stay open is 60 second 

 

 

Info  

 

In order to receive information on the numbers and special numbers stored in unit’s memory send the 
following SMS command:   

P.1234INFO

 

 

 

Disable/Enable the unit

 

The unit default status is enabled. In order to disable the unit send the following SMS  

P.1234EN.0 

I

n order to enable the unit to function send

 

P.1234EN.1

 

 

 

Open All  

 

The "Open All" feature will allow the gate to open for any one that calls the unit.  
To enable this feature send SMS  

P.1234open.1

 

To disable this feature send 

P.1234open.0

 

 

 

REST   

 

In order to reset the unit send the following 

P.1234RESET 
 

 
 