5.
Programming Users’ Phone Numbers (UPN)
Program-in up to 1000 phone numbers (Users’ Phone Numbers) to activate the unit’s relay with
their phones.
For programming the
FIRST Phone Number
:
Press
001 + * + phone #
=> a long beep to confirm.
Note: The unit will announce the phone number after each programming to confirm.
For programming the
SECOND Phone Number
:
Press
002 + * + phone #
=> a long beep to confirm.
‘’
‘’
For programming the
999
th
Phone Number
:
Press
999 + * + phone #
=> a long beep to confirm.
TO EXIT
Program Mode :
Press
* + 0 + #
= > the unit will exit Program Mode and hang up.
Please Note !
•
The unit will automatically hang up if no response is received within 1 minute during programming.
•
Do not forget to turn OFF Dipswitch No. 1 after existing program mode.
•
During the programming mode, an invalid command will be indicated by two short beeps
.
In
Program Mode
you also can:
6. To DELET
a specific
known phone number
from the memory do as follows:
Press
* + 4
+ “
The phone number you want to delete
” + #
=> a long beep to confirm
.
7. For
DELETING
all the phone numbers
except the MASTER phone number;
Press
* + 4 + * + * + * + #
=> a long beep to confirm.
N o t e !
For deleting the MPN you must enter a new MASTER Phone Number only.
8. For getting the next available empty memory cell number or the number of UPNs in the unit:
Press * + 1 + #
=>
The system will announce the next empty cell number by saying individual numbers; i.e.
If the next empty memory cell is Cell Number “026” the system will say: Zero , Two , Six
9. In program mode you can activate the output relay (according to the Function chosen) by :
Press
* + 5 + #
=> a long beep to confirm.
10. SECURITY LOCK
The unit will enter program mode automatically when the “master” number calls and allows the
user to lock or unlock the unit as follows:
To
LOCK
the system: Press
* + 2 + #
=> a long beep to confirm
To
UNLOCK
the system: Press
* + 3 + #
=> a long beep to confirm .