【4DI + 2DO】
MA01-AXCX4020
Page 1: ...4DI 2DO MA01 AXCX4020...
Page 2: ...is given including but not limited with respect to the accuracy correctness reliability and fitness for a particular purpose of the information This document may be revised by EBYTE at any time For m...
Page 3: ...eproduction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is prov...
Page 4: ...realize remote acquisition and control functions Main Features Support Modbus RTU protocol Support various configuration software PLC touch screen RS485 acquisition and control IO DC 8 28V power supp...
Page 5: ...need to prepare a computer converter power supply screwdriver and other related auxiliary materials details as follows Chart 2 1 1 Device list Order Device Number 1 IO device 1 2 USB to serial convert...
Page 6: ...5 Wiring 2 2 3 Overall wiring diagram 1 After the equipment is powered on the power indicator POWER is always on and the equipment power supply is normal 2 Switch input DI wiring connect the control b...
Page 7: ...right 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 6 2 3 Setting 2 3 1 Get connected Figure 2 3 1 Software interface Steps 1 Open the serial port find the corresponding device port number the...
Page 8: ...ow click Search Device and the log window on the right will start refreshing the search information After the connected device is displayed in the device column of the device window click the Stop Sea...
Page 9: ...2 MA01 AXCX4020 4DI 2DO 4 way 2 way MA02 AXCX4020 4 way 2 way MA01 XACX0420 4AI 2DO 4 way 2 way MA02 XACX0420 4 way 2 way MA01 AACX2220 2DI 2AI 2DO 2 way 2 way 2 way MA02 AACX2220 2 way 2 way 2 way MA...
Page 10: ...RTU protocol Device address 1 247 default address 1 DI Number of DI 4 way Interface Type Dry node Trigger method Rising edge falling edge level default level Filter parameter 1 16 default 6 Acquisiti...
Page 11: ...nd RVV 2 0 75 wire 2 Grounding 8 28V 3 B RX RS485 corresponding to B Recommend RVSP 3 0 5 wire 4 A TX RS485 corresponds to A 5 GND Signal ground 6 COM Input channel common Recommend RVV 2 0 5 wire 7 D...
Page 12: ...2DO MA01 AXCX4020 User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 11 Chart 3 4 1 dimensioned drawing 3 5 Installation The equipment is installed with guide rail and positio...
Page 13: ...ion the maximum count is 65535 the count is automatically cleared when 65535 is exceeded The switch input DI supports three trigger modes rising edge falling edge and level the default level trigger m...
Page 14: ...w DI Using C type relay output normally open normally closed the single channel output supports a maximum load contact capacity of 30V 10A or 250V 10A Each DO output is designed with an output indicat...
Page 15: ...The switch output DO terminal is consistent with the DI input terminal Note Multiple switch output DO terminals can be set to follow one DI input terminal and one switch output DO terminal can not be...
Page 16: ...DIP switch can switch different hardware addresses and the binary system represents the 5 digit DIP switch The 5 direction indicates the high position and the 1 direction indicates the low position T...
Page 17: ...et the software address offset address to realize a single bus to connect up to 247 devices After changing the address you need to power off and restart the new address to take effect Note For the fol...
Page 18: ...nual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 17 5 Port wiring 5 1 Switch input DI port wiring 5 1 1 Two wire switch wiring Figure 5 1 1 Wiring diagram of two wire switch 5 1 2 T...
Page 19: ...yte Electronic Technology Co Ltd 18 5 1 3 Three wire sensor wiring Figure 5 1 3 Three wire sensor wiring diagram 5 2 Switch output DO port wiring 5 2 1 The output terminal directly controls the load s...
Page 20: ...output terminal control contactor Remarks The above figure takes the contactor coil voltage AC 220V as an example The coil voltage of different contactors may be different 5 2 3 Output terminal contro...
Page 21: ...u Ebyte Electronic Technology Co Ltd 20 6 Software use 6 1 Software Installation The configuration tool software is driver free installation directly double click the exe file to open it and use it Fi...
Page 22: ...1 IO Demo interface Figure 6 2 1 Software IO demo interface 1 Device window Display the information of the currently connected device serial number device model device address firmware version Figure...
Page 23: ...Serial port parameter window interface 3 Log window Display the running log information send and return data commands during the configuration and use of the device Figure 6 2 4 Log window interface 4...
Page 24: ...Figure 6 2 5 Switch output DO interface 6 Analog input AI This function is limited to devices that support AI Display the status of the analog input AI port current quantity engineering quantity graph...
Page 25: ...interface 1 Counting demonstration Display DI count information and clear settings This function is limited to devices that support DI Figure 6 2 9 Counting demo interface 2 DI related Set the DI func...
Page 26: ...erminals can be set to follow one DI input terminal and one switch output DO terminal can not be set to follow multiple DI input terminals Follow mode is limited to devices that support DI Figure 6 2...
Page 27: ...aud rate setting interface Support setting check digit can set check digit none odd check even check default no check Figure 6 2 16 Check Digit Setting Interface 6 3 Device status query The configurat...
Page 28: ...DO MA01 AXCX4020 User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 27 1 IO demo interface Figure 6 3 1 Device status query IO demo interface 2 Basic setting interface Figure 6...
Page 29: ...3 3 Device status query advanced setting interface 6 4 Equipment status control Device status control the device supports ModBus standard command control It also supports configuration software graphi...
Page 30: ...User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 29 Method 2 Input command control Device address 1 Function open DO 1 output Sending 01 05 00 00 FF 00 8C 3A including CRC c...
Page 31: ...DO After writing the state of the DO is the set state after the next restart 0x01 0x05 0x0F 10000 0x0000 4 DI value RW 0x00 0xFF represents the current level signal of DI 0x02 42527 0x09DF 4 DI count...
Page 32: ...0x10 42000 0x07D0 7 Module model R See model definition table 0x03 42012 0x07DC 2 Firmware version R Firmware version number 0x03 42014 0x07DE 10 Module name RW The name can be up to 20 bytes long inc...
Page 33: ...the following values 20 01 01 02 XX XX Device ModBus address function code Number of bytes of data Status data returned CRC check code The status data 02 returned above indicates that the output DO2 i...
Page 34: ...0001 7 2 4 Write multiple holding registers Use 10 function code to write commands for multiple holding registers for example set the working mode of DO1 DO4 at the same time 20 10 05 78 00 04 08 0001...
Page 35: ...ode Register address Write value CRC check code The DO1 coil is turned on 7 2 6 Write multiple DO coil states Use 0F function code to write a single command for example set the working mode of DO1 to...
Page 36: ...he revision date Revised description Maintainer 1 0 2021 08 30 The initial version LC 1 1 2023 3 13 Content Revisions LT About us Technical support support cdebyte com Documents and RF Setting downloa...