4 Parameters
4.1 Model details
Model
Freq.
TX Power
Test range
feature
Application features
Hz
dBm
m
E92-DTU(2G4HD12) 2.4G
12
1200
Point-to-point frequency hopping
Bidirectional continuous transmission
Suitable for environments
with long communication
distances and susceptible to
interference
★
Test range conditions
: sunny and clear sky, test environment is open without obstruction, 12V/1A power supply, the
device is 2 meters above the ground, and the default parameters are used.
4.2 Regular parameters
No.
Name
Value
Description
1
Product Size
228*228*68 mm
See installation dimensions for details
2
Product Weight
1700g
3
Operating
temperature
-40
℃~
+85
℃
Meet the need of industrial use
4
Voltage range
8
~
28V DC
Recommend to use 12V or 24V
5
Communication
Interface
RS485
3.81 Terminal block
6
Baud rate
Default 9600
Baud rate range 1200
~
3M
4.3 Frequency range and Channels
Mode
Main Freq.
Range
Channel Width
Channels
Hz
Hz
Hz
E92-DTU(2G4HD12)
2.4G
2.4
~
2.48G
1M
80
(
full duplex
)
Summary of Contents for E92-DTU