background image

Chengdu Ebyte Electronic Technology Co,;Ltd

E90-DTU (230SL22-GPRS) User Manual

Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd

16

4

The radio frequency terminal has the function of Listen before talk (LBT), which enables the radio

station to actively Listen to the environmental noise of the channel after sending data to the server. If the noise
exceeds the threshold, the transmission will be delayed. This function can greatly improve the success rate of
radio communication with radio frequency in harsh environment. This function can be used for network
transmission and conflict prevention.

5

Fixed point transmission: support address function, radio frequency terminal can transmit data to

other wireless devices at any address and any channel to achieve networking, relay and other applications: for
example, the radio needs to transmit data to E22 cofrequency series module B (address 0x00 01, channel 0x80),
and its communication format is: 0001 80 AA BB CC, where 0001 is the address of module B and 80 is the
channel of module B, then module B can receive AA BB CC, and other modules do not receive data (the same
is true for E90-DTU (xxx-SLXX) series stations).

6

LoRa spread spectrum: LoRa direct sequence spread spectrum technology will bring more

communication distance; Low transmission power density, not easy to cause interference to other equipment;

9

Factory recovery

There are two ways to restore the factory

Software restore factory: users can configure software through the E90-DTU (230SL22-GPRS) officially
provided. In the configuration mode of GPRS/2G network transmission and RF configuration mode, click
the "restore from factory" button to reset the GPRS/2G module and RF module. Note: if the "restore
factory" button is clicked in the configuration mode of GPRS/2G network pass-through, after all
parameter modification operations are completed, the "module restart" button should be clicked again to
enable the restored factory or configured GPRS/2G network pass-through parameters to take effect.

Hardware restore factory

The user can press the Reload button on the side of the radio station for 4~10S

and all parameters will be restored to the factory setting. At this time, the system will automatically
switch to the communication mode.

Summary of Contents for E90-DTU 230SL22-GPRS

Page 1: ...E90 DTU 230SL22 GPRS...

Page 2: ...Ebyte Electronic Technology Co Ltd 1 Content 1 OVERVIEW 2 1 1 INTRODUCTION 2 1 2 FEATURES 2 1 3 STATION SYSTEM PARAMETERS 3 1 4 PIN DEFINITION AND SIZE 5 2 QUICK START 8 2 1 HARDWARE PREPARATION AND C...

Page 3: ...a USB cable for parameter configuration without the need to install the driver it is easy to change user defined parameters This chapter is a quick introduction to E90 DTU 230SL22 GPRS products It bui...

Page 4: ...nnection characteristics GPRS multi slot class 12 default GPRS multi slot class 1 12 configurable GPRS mobile station class B GPRS Data features GPRS data downlink transmission up to 85 6 KBPS GPRS up...

Page 5: ...rate 115200 bps No modification supported The antenna interface SMA Interface RF signal output 50 ohm characteristic impedance Station system parameters Flow loss value typical value 66 5mA 12V Idle...

Page 6: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 230SL22 GPRS User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 5 1 4 Pin Definition and Size...

Page 7: ...on long press time no requirement 6 USB Micro USB parameter configuration interface 7 Reload Press 4 10s to restore the factory Settings 8 PWR Red power indicator 9 WORK Yellow data transmission indic...

Page 8: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 230SL22 GPRS User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 Size...

Page 9: ...22 GPRS device and E22 230TXXS module 5V 20V Power adapter USB switch to TTL module and USB wire GPRS LTE Sucker antenna Computer browser visit Chengdu Ebyte official website www ebyte com download th...

Page 10: ...rrectly connected the message box on the right side will prompt device ready 3 After entering the GPRS 2G network pass through configuration mode the parameters of GPRS 2G module can be configured in...

Page 11: ...the RF module in the setting of relevant parameters After the configuration is completed click the save RF parameters button After completion as shown in the following figure 5 After the configuratio...

Page 12: ...e restart button and directly click the enter communication state button in the RF mode After completion as shown in the following figure 6 Within 30 seconds after the communication state is entered i...

Page 13: ...Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 12 8 Use the serial port assistant to send data to E22 230TXXS module If E90 DTU 230SL22 GPRS receives the data sent by E22 230TXXS the W...

Page 14: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 230SL22 GPRS User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 13 b E90 DTU 230SL22 GPRS sends data to E22 230TXXS...

Page 15: ...meters c RF configuration mode this mode allows users to configure radio RF parameters d Mode switch use the official E90 DTU 230SL22 GPRS to configure the upper computer for mode switch and parameter...

Page 16: ...th the server you can choose whether to clear the cached data By default clearing the cache will be closed The maximum packet length from the local cache is 256 bytes 7 The cloud transmission function...

Page 17: ...nel of module B then module B can receive AA BB CC and other modules do not receive data the same is true for E90 DTU xxx SLXX series stations 6 LoRa spread spectrum LoRa direct sequence spread spectr...

Page 18: ...chnology Co Ltd E90 DTU 230SL22 GPRS User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 17 3 Application model 1 E22 230TXXS E90 DTU 230SL22 GPRS Server A 2 E90 DTU 230SLxx E90...

Page 19: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 230SL22 GPRS User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 3 Ebyte cloud transmission 4 Application in buildings...

Page 20: ...rectly If they are connected try to press the Reset button re plug the power cord or re plug the USB Server A of this product is always open After successful initialization it will automatically estab...

Reviews: