5. Precautions

The first Socket of this module is always open. After successful initialization, it will automatically establish a connection

with the configured network server.

After the module is powered on, it has not been able to initialize successfully, that is, there is no indication on the State

indicator for more than 30 seconds. At this time, check whether the module is installed normally, whether the SIM card is
inserted normally, and whether the SIM has failed.

The short connection function can be used to reduce the connection pressure of multiple devices to the server. When the

short connection function is enabled, when there is no data on the network or serial port for longer than the short connection
setting period, the module will actively disconnect the connection. After disconnection, the network cannot send data. The local
serial port sends valid data, and the module will immediately communicate with The server establishes a connection. If the local
cache clear function is turned off at this time, the data packet will be cached (maximum 10K bytes). After the connection is
successful, the data will be sent to the server. If the local cache clear function is enabled, The packet will be discarded.

The heartbeat function is used to maintain the connection after the module has successfully established a connection with the

server. In the network, if there is no data transmission for a long time after the client has successfully established a connection
with the network server, the Socket link may appear "dead", that is, the chain The path exists, but data cannot be sent or
received. Therefore, in actual use, it is recommended to enable the heartbeat packet function to ensure the reliability of the
network link.

In actual use, it is normal for the data delay difference between the two communications to be different.

After the module closes the protocol transmission, the maximum single packet length supported by a single link is 10K bytes.

The local serial port or network single transmission of data packets exceeding this length may cause packet abnormalities; open
the distribution protocol, each SocKet A single link packet can support up to 1024 bytes (the serial port packet length
configured by the user),

When the device serial port outputs the words "pdp error, device will be reset!", it means that the PDP context is disabled by

the network side. It may be that the SIM card is loose or the current network channel is occupied abnormally.

The SMS function requires the inserted SIM card to support the SMS service, and the IoT card cannot send and receive SMS;

when the device sends a SMS, the device responds OK only to indicate that the module has sent the SMS, but it does not mean
that the device has received the SMS.

After modifying the serial port frame time, the AT command also needs to be configured to operate according to this frame

time. For example: after setting this parameter to 2000ms, the next time you power on the device to configure the device
parameters, you need to send'+++' After that, send a valid AT command within the period of more than 2000ms and less than
3000ms to enter the AT mode normally

Summary of Contents for E842-DTU

Page 1: ...Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd E841 DTU EC03 485 User manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 1 ...

Page 2: ...anical size and pin definition 错误 未定义书签 4 Quick start and function introduction 错误 未定义书签 Quick start 错误 未定义书签 4 1 Hardware preparation 错误 未定义书签 4 2 Network transparent transmission mode 错误 未定义书签 4 3 MQTT model 错误 未定义书签 Function introduction 错误 未定义书签 4 4 ModBus TCP to RTU function 错误 未定义书签 4 5 Serial port packaging function 错误 未定义书签 4 6 Network AT function 错误 未定义书签 4 7 Register package function 错误 ...

Page 3: ... rights Reproduction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided as is and EBYTE assumes no liability for the use of the information No warranty either express or implied is given including but not limited with respect to the accuracy correctness reli...

Page 4: ... RTUs and Modbus TCP to each other 1 2 Features Use a 4G CAT1 solution Ability to meet almost all M2M application needs Supports transparent data transfer Supports TCP UDP network protocols Support heartbeat package registration package Supports network configuration parameters Supports simultaneous sending and receiving of 2 Socket links Supports automatic conversion of Modbus RTUs and Modbus TCP...

Page 5: ...mmended Operating temperature sc 40 85 Industrial grade 2 2 Working parameters The name of the argument The value of the argument description The attribute parameters Support for bands LTE TDD B34 B38 B39 B40 B41 LTE FDD B1 B3 B5 B8 Network protocol characteristics Supports the TCP UDP MQTT protocol Hardware features Antenna interface SMA K The power interface 5 08 Terminals The communication inte...

Page 6: ...of the other RS485 devices that are external 2 485_B The B side of the other RS485 devices that are external 3 GND earthing 4 PWR Power LED 5 DC Power adapter interface power supply range 8to28VD C 6 Restore The station restores factory settings When the Restore dial continues down 3to10S dial up to restore the radio parameters to the factory settings 7 YES Sim card slot 8 ON Antenna interface SMA...

Page 7: ...the A side of the RS485 device B to the B side of the RS485 device andG ND to the external device 5 PWR Power LED Lit when the power is on 6 STATE The in network status indicator Flashing Power to the search network on the device Solid The device is successfully attached to the network 7 DATA Data transceiver indicator Send receive data flashing 8 LINE The data link light Solid SocketA connects to...

Page 8: ...eds to install USB re serial driver first download the parameter configuration software in advance you can go to our official website to download 4 2 Network transmission mode Open the parameter configuration software 1 Select the appropriate port number 2 Select Baud Rate 115200 factory default 3 Select Check Data Stop None 8 1 factory default 4 Open the serial port 5 Click to enter configuration...

Page 9: ... the device test 12 After popping up the interface click Continue access go to the Step 6 server test interface 13 The phone sends data and the device receives it 14 Device send data mobile phone reception two way testing normal 4 3 MQTT mode Open the parameter configuration software 1 select the appropriate port number 2 select Baud Rate 115200 factory default 3 select check data stop bit None 8 ...

Page 10: ...cription publishing message level 11 Click to save all parameters 12 Click the device to restart Introduction to the feature 4 4 ModBus TCP to RTU feature When this option is turned on using parameter configuration software the ModBus TCP and RTU are automatically converted When the device receives the data it will detect whether the data meets the Modbus RTU or ModbusTCP protocol and if it does s...

Page 11: ...break time When the frame break time receives data for a serial port the interval between two bytes of phase collar is constantly detected and if it is greater than the user s configured time which can be set to 50 2000ms the device automatically sends the previously received data as a packet to the network side Package length When packaging the length of the serial to receive data the currently r...

Page 12: ... of data and customizing the maximum length of the registration packet by 80 bytes up to 40 bytes when set to HEX format which can be set by parameter configuration software 4 8 Heartbeat pack function In the idle state of network communication the heartbeat package is used for network state maintenance The heartbeat period can be set from 0 to 65535 seconds with a maximum length of 80 bytes up to...

Page 13: ...gdu Ebyte Electronic Technology Co Ltd 13 4 9 Serial upgrade Open the E Yi Special Serial Upgrade Tool select the serial port and open it import the version firmware that needs to be upgraded click the Start Upgrade button The device is powered off and restarted automatically completing the upgrade ...

Page 14: ...Chengdu Yiyit Electronic Technology Co Ltd E842 DTU EC03 485 User manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 14 ...

Page 15: ... for a long time after the client has successfully established a connection with the network server the Socket link may appear dead that is the chain The path exists but data cannot be sent or received Therefore in actual use it is recommended to enable the heartbeat packet function to ensure the reliability of the network link In actual use it is normal for the data delay difference between the t...

Page 16: ...t APNsupport rail housing high protection DC power supply E841 DTU EC03P 232 4G Cat1 RS232 8 28V DC 4G DTU MQTTsupport APNsupport rail housing high protection DC power supply E842 DTU EC03 485 4G Cat1 RS485 85 265V AC 4G DTU MQTTsupport APN rail housing AC power supply E842 DTU EC03 232 4G Cat1 RS232 85 265V AC 4G DTU MQTTsupport APN rail housing AC power supply E842 DTU EC03P 485 4G Cat1 RS485 85...

Page 17: ...aintainer 1 0 2017 10 16 The initial version huaa 1 1 2021 07 15 Content reorganization LYL About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Phone 86 028 61399028 Web www ebyte com Address B5 Mould Park 199 Xiqu Ave High tech District Sichuan Ch...

Reviews: