![Ebyte E820-AIO User Manual Download Page 8](http://html.mh-extra.com/html/ebyte/e820-aio/e820-aio_user-manual_530394008.webp)
8
3.2 Baud rate code table
Baud rate code table
0
1200
1
2400
2
4800
3(default)
9600
4
19200
5
38400
6
57600
7
1152200
3.3 Parity bit code table
Parity bit code table
0(default)
No parity
1
Even parity
2
Odd parity
40034
2
Baud rate
Read/write
see more in baud rate table
40035
2
parity bit
Read/write
see more in parity bit table
40036
2
Lower limit register
Read/write
0-65535(Lower limit register must be less
than the Upper limit register . After the
configuration, channel 1-4 will be the
range of upper and lower limits.
40037
2
Upper limit register
Read/write
40038
2
Conversion value for
channel 1
Read only
The original data value transformed by
the analog quantity of channel 1
40039
2
Conversion value for
channel 2
Read only
The original data value transformed by
the analog quantity of channel 2
40040
2
Conversion value for
channel 3
Read only
The original data value transformed by
the analog quantity of channel 3
40041
2
Conversion value for
channel 3
Read only
The original data value transformed by
the analog quantity of channel 4