![Ebyte E70-915T14S2 User Manual Download Page 19](http://html.mh-extra.com/html/ebyte/e70-915t14s2/e70-915t14s2_user-manual_530546019.webp)
Chengdu Ebyte Electronic Technology Co,;Ltd E70-915T30S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 18
1
0
8E1
1
1
8N1
(
equal to 00
)
5
4
3
TTL UART baud rate
(
bps
)
UART baud rate can be different between
communication parties
The UART baud rate has nothing to do with wireless
transmission parameters & won’t affect the wireless
transmit / receive features.
0
0
0
1200bps
0
0
1
2400bps
0
1
0
4800bps
0
1
1
9600bps
(
Default
)
1
0
0
19200bps
1
0
1
38400bps
1
1
0
57600bps
1
1
1
115200bps
2
1
0
Air data rate
(
bps
)
The lower the air data rate, the longer the
transmitting distance, better anti-interference
performance and longer transmitting time
The air data rate must keep the same for both
communication parties.
0
0
0
2.5kbps
0
0
1
5kbps
0
1
0
12kbps
(
Default
)
0
1
1
28kbps
1
0
0
64kbps
1
0
1
168kbps
1
1
0
168kbps
1
1
1
168kbps
4
CHAN
7
6
5
Packet length (only for subpackage
mode)
Under continuous transmitting mode (M0=1 M1=0
M2=0), this parameter is invalid
0
0
0
16 bytes
0
0
1
32 bytes
0
1
0
64 bytes
(
Default
)
0
1
1
128 bytes
1
0
0
256 bytes
1
0
1
512 bytes
1
1
0
1024 bytes
1
1
1
2048 bytes
Communication Channel
00H~1FH, 907~922.5MHz
,(
Default
)
10H
(
915M
)
5
OPTION
7
Fixed transmission (similar to MODBUS
)
When it is 1, the first three bytes of each user data
frame can be used as high/low address and channel.
The module changes its address and channel when
transmitting. And it will revert to original setting
after the process is completed.
It is transparent transmission under continuous
mode.
0
Transparent transmission mode (Default
)
1
Fixed transmission mode
6
5
4
wireless wake-up time
This parameter is only valid for mode 4, 6.
For mode 6, the wake-up time will affect the WOR
0
0
0