Chengdu Ebyte Electronic Technology Co,;Ltd E70-915T14S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 18
1
1
1
168kbps
4
CHAN
7
6
5
Packet length (only for subpackage
mode)
Under continuous transmitting mode
(M0=1 M1=0 M2=0), this parameter is
invalid
0
0
0
16 bytes
0
0
1
32 bytes
0
1
0
64 bytes
(
Default
)
0
1
1
128 bytes
1
0
0
256 bytes
1
0
1
512 bytes
1
1
0
1024 bytes
1
1
1
2048 bytes
Communication Channel
00H~1FH,907~922.5MHz
,(
Default
)
10H
(
4915M
)
5
OPTIO
N
7
Fixed transmission (similar to MODBUS
)
When it is 1, the first three bytes of each
user data frame can be used as high/low
address and channel. The module changes
its
address
and
channel
when
transmitting. And it will revert to original
setting after the process is completed.
It is transparent transmission under
continuous mode.
0
Transparent transmission mode (Default
)
1
Fixed transmission mode
6
5
4
wireless wake-up time
This parameter is only valid for mode 4,
6.
For mode 6, the wake-up time will affect
the WOR cycle of the module, and affect
the power consumption.
For mode 4, the wake-up time decides the
number of wake-up code before
transmission so as to ensure the wake up
the module in mode 6.
Generally, mode 4 and 6 shall be used
jointly and the wake-up time on both
modules shall be the same.
0
0
0
500ms
0
0
1
1000ms(Default)
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
3
FEC switch
After turn off FEC, the actual data
transmission rate increases while anti-
interference ability decreases. Also, the
transmission distance is relatively short.
Both communication parties must keep on
the same pages about turn-on or turn-off
FEC.
0
Turn off FEC
1
Turn on FEC (Default)
)
2
IO drive mode
This bit is used to the internal pull-up
resistor. It also increases the level’s
0
TXD and AUX push-pull outputs, RXD pull-up inputs