In any mode, When M0=1,M1=1, it will enter the low power consumption mode. In this mode, the serial port parameters
are fixed at 115200, 8N1.
8. Quick start
8.1 Communication between normal node and coordinator
Coordinator configuration
Open the serial port assistant, select the serial port corresponding to the device, and set the serial port parameters
(default is 115200, 8N1)
Enter "+++" without line breaks to enter the AT command mode. When receiving "Enter AT Mode", the AT mode is
successfully entered. As shown in Figure 5-1:
Enter "AT+WMCFG=0" with line breaks to and configure the device as coordinator mode. As shown in Figure 6-1:
Figure 6-1
Then enter “AT+RSTART” to restart the device with a line break. The coordinator configuration is complete. As
shown in Figure 6-2:
Figure 6-2
Normal node configuration
Open the serial port assistant and select the serial port corresponding to the device. Set the baud rate to 115200, the
data bit to 8 bits, the parity bit to none, the stop bit to 1 bit, and the flow control is disabled, open the serial port.
Enter "+++" without line breaks to enter the AT command mode. When receiving “Enter AT Mode", the AT mode is
successfully entered.
Enter "AT+WMCFG=1" with line breaks to to configure the device as normal mode. As shown in Figure 6-3: