Chengdu Ebyte Electronic Technology Co,;Ltd
E62-433T30D user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
11
2
FHSS
nums
The quantity of frequency hopping channel
(default 0AH)
Both sides must keep the same. The
more quantity of frequency-hopping
channel, the better anti-interference
while synchronization time is longer
for both sides. Otherwise the less
quantity of frequency-hopping channel,
the worse anti-interference while
synchronization time is shorter.
3
SPED
Rate parameter, including UART baud rate
and air data rate
7, 6 UART parity bit
00
:
8N1
(
default
)
01
:
8O1
10
:
8E1
11
:
8N1
(
equal to 00
)
-----------------------------------------
5, 4, 3
TTL UART baud rate
(
bps
)
000
:
1200bps
001
:
2400bps
010
:
4800bps
011
:
9600bps
(
default
)
100
:
19200bps
101
:
38400bps
110
:
57600bps
111
:
115200bps
-----------------------------------------
2, N/A
-----------------------------------------
1, 0
Air data rate
(
bps
)
00
:
16Kbps
01
:
32Kbps
10
:
64Kbps
(
default
)
11
:
128Kbps
UART mode can be different between
communication parties
-----------------------------------------------
UART baud rate can be different
between communication parties
The UART baud rate has nothing to do
with wireless transmission parameters
& won’t affect the wireless transmit /
receive features.
----------------------------------------------
0 is recommended.
----------------------------------------------
The lower the air data rate, the longer
the
transmitting
distance,
better
anti-interference
performance
and
longer transmitting time
The air data rate must keep the same