Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd.
15
3
C2 + working
parameters
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in
total and must be send in succession. ( Not save the parameters when
power-down )
4
C3+C3+C3
Three C3 are sent in hexadecimal format. The module returns the version
information and must be send in succession.
7.1 Default parameter
Default parameter values
:
C0 00 00 18 20 00
Model
Frequency Address
Channel
Air data rate
Baud rate
Transmitting
Powr
E43-900T13S
3
868.8MHz
0x0000
0x2E
1.2kbps
9600
13dBm
7.2 Reading operating parameters
Instruction format
Description
C1+C1+C1
In sleep mode
(
M0=0
,
M1=1
)
,
User gives the module instruction (HEX format): C1
C1 C1,
Module returns the present configuration parameters.
,
For example
:
C0 00 00 18 2E
00
。
7.3 Reading version number
Instruction format
Description
C3+C3+C3
In setting mode
(
M0=0
,
M1=1
),
User gives the module instruction (HEX format):
C3 C3 C3
,
Module returns its present version number, for example
:
C3 43 xx yy
;
43 here means the module model (E43 series); xx is the version number and yy
refers to the other module features.
7.4 Parameter setting instruction
No.
Item
Description
Remark
0
HEAD
Fix 0xC0 or 0xC2, it means this frame data is control
command
Must be 0xC0 or 0xC2
C0: Save the parameters when
power-off
C2: Do not save the parameters when
power-off.
1
ADDH
High address byte of module
(
the default 00H
)
00H-FFH
2
ADDL
Low address byte of module
(
the default 00H
)
00H-FFH
3
SPED
Rate parameters, including serial port rate and air data
rate
7, 6: reserved bit, It’s recommend to write 0
-----------------------------------
UART baud rate can be different