Chengdu Ebyte Electronic Technology Co,;Ltd
E30-170T27D user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
10
transmit data at this circumstance, it may cause overtime when the module is waiting for the user data, or
transmitting wireless sub package.
When AUX = 1, it does not mean that all the UART data of the module have been transmitted already, perhaps the
last packet of data is still in transmission.
5.6.3 Configuration procedure of module
Only happened when power-on resetting or exiting sleep mode
5.6.4 Notes for AUX
No.
Description
1
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which
means if it meets each of any low level output condition, AUX outputs low level, if none of the low level condition
is met, AUX outputs high level.
2
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms
since AUX outputs high level, the mode switch will be completed.
3