Chengdu Ebyte Electronic Technology Co., Ltd.
E22-900T30DC User Manual
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd.
5
distance.
1.3 Application
Home security alarm and remote keyless entry;
Smart home and industrial sensors;
Wireless alarm security system;
Building automation solutions;
Wireless industrial-grade remote control;
Health care products;
Advanced Meter Reading Architecture(AMI);
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Remark
Min.
Max.
Power supply
(
V
)
0
5.5
Voltage over 5.5V will cause permanent
damage to module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules are
used in short distance
Operating temperature
(
℃
)
-40
85
/
2.2 Operating parameter
Main parameter
Performance
Remark
Min.
Typ.
Max.
Operating voltage
(
V
)
3.3
5.0
5.5
≥5.0 V ensures output power
Communication level
(
V
)
3.3
For 5V TTL, It is recommended to add
level conversion
Operating temperature
(
℃
)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
850.125
868.125
930.125
Support ISM band
Power
consumpti
on
TX current
(mA)
-
650
-
Instant power consumption
RX current
(mA)
-
16
-
Sleep current
(
μA
)
-
2
-
Software is shut down
Max Tx power
(
dBm
)
29.5
30.0
30.5
Receiving sensitivity
(
dBm
)
-146
-147
-148
Air data rate 2.4kbps
Air data rate
(
bps
)
0.3k
2.4k
62.5k
To control via user’s program