Command format
Description
1
Set register
Command: C0+starting parameters
Response: C1+starting parameters
E.g 1: Channel is 0x09
command starting address length parameter
Send: C0 05 01 09
Returen: C1 05 01 09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air data
rate (1.2K).
Send: C0 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
2
Read register
Command: C1+starting parameters
Response: C1+starting parameters
E.g 1
:
Read channel
command starting address length parameter
Send: C1 05 01
Returen: C1 05 01 09
E.g 2: Read module address, network address, serial port and air data rate.
Send: C1 00 04
Return: C1 00 04 12 34 00 61
3
Set
temporary
registers
Command: C2+starting parameters
Response: C1+starting parameters
E.g 1: Channel is 0x09
command starting address length parameter
Send: C2 05 01 09
Returen: C1 05 01 09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air data
rate (1.2K).
Send: C2 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
5
Wireless
configuration
Command: CF CF + normal command
Respond
:
CF CF + normal respond
E.g 1: Channel is 0x09
Command head command starting address length parameter
Send: CF CF C0 05 01 09
Returen: CF CF C1 05 01 09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air data
rate (1.2K).
Send: CF CF C2 00 04 12 34 00 61
Return: CF CF C1 00 04 12 34 00 61
6
Wrong format
Wrong format respond: FF FF FF