E22-230T22D User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
5
1.3 Application Scenarios
Home security alarms and remote keyless entry.
Smart home and industrial sensors, etc.
Wireless alarm security systems.
Building automation solutions.
Wireless industrial grade remote controls.
Healthcare products.
Advanced Meter Reading Architecture (AMI).
Automotive industry applications.
2 Specifications
2.1 Limit Parameters
Main parameters
Performance
Remarks
Minimum value
Maximum value
Supply voltage (V)
0
5.5
Permanent module burnout above 5.5V
Blocking Power (dBm)
-
10
Less probability of burnout with close use
Operating temperature (
℃
)
-40
+85
Industrial Grade
2.2 Working Parameters
Main parameters
Performance
Remarks
Minimum
value
Typical
values
Maximum
value
Operating voltage (V)
2.3
5.0
5.5
≥3.3V for guaranteed output power
Communication level (V)
3.3
Use of 5V TTL recommended plus level shift
Operating temperature (
℃
)
-40
-
+85
Industrial grade design
Operating frequency band
(MHz)
220.125
-
236.125
ISM band support
Power
consumption
Emission
current
(mA)
107
Instantaneous power consumption
Receiving
current
(mA)
11
Dormant
current (uA)
2
Software shutdown