Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120A User Manual
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
1
FF
:
Command terminator
Configuration return
:
FC CMD STATUS
FC:
Fixed head
CMD:
Actual named ID
Status: 00 operation succeeded
01 operation failed
6.5.2
Read instruction set
Command description
Command
ID
Command format
Command example
Read device type
01
Send
:
FE 01 01 FF
Return
:
FB 01 dev_type
Send
:
FE 01 01 FF
Return
:
FB 01 03
Read network state
02
Send
:
FE 01 02 FF
Return
:
FB 02 nwk_state
Send
:
FE 01 02 FF
Return
:
FB 02 02
Read network PAN_ID
03
Send
:
FE 02 03 FF
Return
:
FB 03 pan_id
Send
:
FE 02 03 FF
Send
:
FB 03 FE 5B
Read local short address
05
Send
:
FE 02 05 FF
Return
:
FB 05 Short_Addr
Send
:
FE 02 05 FF
Return
:
FB 05 F6 FA
Read local MAC address
06
Send
:
FE 08 06 FF
Return
:
FB 06 Mac_Addr
Send
:
FE 08 06 FF
Return
:
FB 06 1F 1C 21 FE
FF 57 B4 14
Read short address of father
nodes
07
Send
:
FE 02 07 FF
Return
:
FB 07
Coor_shortAddr
Send
:
FE 02 07 FF
Return
:
FB 07 00 00
Read short MAC address of
father nodes
08
Send
:
FE 08 08 FF
Return
:
FB 08 Coor
_Mac_Addr
Send
:
FE 08 08 FF
Return
:
FB 08 0C 46 0C FE
FF 9F FD 90
Read network group number
09
Send
:
FE 01 09 FF
Return
:
FB 09 group
Send
:
FE 01 09 FF
Return
:
FB 09 01
Read communication channel
0A
Send
:
FE 01 0A FF
Return
:
FB 0A channel
Send
:
FE 01 0A FF
Return
:
FB 0A 0B
Read Send power
0B
Send
:
FE 01 0B FF
Return
:
FB 0B txpower
Send
:
FE 01 0B FF
Return
:
FB 0B 0A
Read UART baud rate
0C
Send
:
FE 01 0C FF
Return
:
FB 0C baud
Send
:
FE 01 0C FF
Return
:
FB 0C 09
Read sleep time
0D
Send
:
FE 01 0D FF
Return
:
FB 0D sleep_time
Send
:
FE 01 0D FF
Return
:
FB 0D 54
Read target short network
address
23
Send
:
FE 02 23 FF
Return
:
FB 23
Dec_ShortAddr
Send
:
FE 02 23 FF
Return
:
FB 23 00 00