background image

E103-W10 User Manual

ESP8285 Serial transfer WiFi module

Summary of Contents for E103-W10

Page 1: ...E103 W10 User Manual ESP8285 Serial transfer WiFi module ...

Page 2: ...mmended wire diagram 6 5 Operating guidance 7 5 1 As TCP Client single connection 7 At the same time the PC side TCP UDP Test Tool displays the connection window 11 5 2 As TCP server single connection 12 6 Network description 15 7 AT command 18 8 FQA 18 8 1 The transmission distance is not ideal 18 8 2 Module is easy to be damaged 18 8 3 BER Bit Error Rate is high 18 9 Production guidance 19 9 1 R...

Page 3: ...uction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided as is and EBYTE assumes no liability for the use of the information No warranty either express or implied is given including but not limited with respect to the accuracy correctness reliability and fi...

Page 4: ...le devices home automation home security personal health care smart appliances accessories and remote control automotive lighting industrial Internet and other fields E103 W10 supports the standard IEEE 802 11b g n protocol which is easily configured to enable network access and minimize developer work and project development time 1 2 Features In ideal conditions the communication distance is 250m...

Page 5: ...2430 2483 5 Support ISM band Max TX power dBm 19 19 5 20 Wifi version 802 11 Tx802 11 b CCK 11Mbps POUT 19 dBm mA 197 Power consumption tested conditions 1 Supply voltage 3 3 V 2 Ambient temperature 25 3 TX power consumption Measured based on a 50 send to air ratio Tx802 11 g OFDM 54Mbps POUT 15 dBm mA 147 Tx802 11 n MCS7 POUT 13 dBm mA 142 Rx802 11 b 1024 bytes 80 dBm mA 73 Rx 802 11 g 1024 bytes...

Page 6: ... up 3 ms each time to receive the Beacon packet of the AP the current is about 0 9 mA C Deep sleep mode is used in scenarios that require Wi Fi connection For applications that a data packet is sent for a long time e g measure the temperature every 100 s It takes 0 3 1 s to connect to the AP after waking up every 300 s and the overall average current is less than 1 mA The flow of 20 μA is obtained...

Page 7: ...s connected to the inside of the module 9 IO16 Input Output GPIO16 Deep sleep wake up 10 ADC Input TOUT ADC port Note ADC port port inside the chip can be used to detect the input in voltage of the VDD3P3 Pin3 Pin4 supply voltage and the TOUT Pin6 both of which cannot be used at the same time 11 EN Input Chip enables end high level effective chip works properly Low level Chip closed small current ...

Page 8: ...s effective EN enable pin high level is effective 4 Wi Fi startup mode 5 The RXD0 of the Wi Fi module is connected to the TXD of the external MCU and the TXD0 of the Wi Fi module is connected to the RXD of the external MCU 5 Operating guidance 5 1 As TCP Client single connection 1 Setting Wi Fi mode Command AT CWMODE 3 SoftAP Station mode Response OK For example GPIO15 GPIO0 GPIO2 Level Boot mode ...

Page 9: ...r Command AT CWJAP SSID password SSID Router name password Key of the router Response OK Example router name E880 IR01 password JSZXE880 3 Checking local IP address AT CIFSR Example CIFSR APIP 192 168 4 1 Router IP address CIFSR APMAC c6 4f 33 d6 4a fc CIFSR STAIP 192 168 1 124 E103 W10 IP address from the router CIFSR STAMAC c4 4f 33 d6 4a fc Example ...

Page 10: ...yright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 9 4 The PC uses a wireless connection to the router 5 The PC views the IP address of the WLAN adapter Wi Fi Using it later when creating the server Open command prompt and writing ipconfig Checking IP address ...

Page 11: ...Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 10 6 Open the network debug assistant on the PC and create the server Using the TCP UDP Test Tool to do the test Create a server with an IP address of 192 168 1 156 and a port of 8080 Starting the server ...

Page 12: ...echnology Co Ltd E103 W10 User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 11 7 E103 W10 connects to PC server as TCP client At the same time the PC side TCP UDP Test Tool displays the connection window ...

Page 13: ...SEND 4 Setting to the data which is about to be sent such as 4 bytes Wait for serial data no return line change no need to check Send new line Response Recv 5 bytes Length of the data received by the serial SEND OK Successfully 9 Data received 5 2 As TCP server single connection 1 Setting Wi Fi mode Command AT CWMODE 3 Soft AP Station mode Response OK ...

Page 14: ...ogy Co Ltd 13 2 Multiple connections AT CIPMUX 1 Response OK 3 Configuration ESP Soft AP AT CWSAP E103 W10 _SOFTAP 12345678 5 3 Response OK 4 Checking local softAP addres example in the following picture is 192 168 4 1 5 Creating TCP server AT CIPSERVER 1 Default port 333 Response OK 6 PC connected to E103 W10 SoftAP ...

Page 15: ...P UDP Test Tool to create TCP Client and connect to the TCP server created by E103 W10 Click connection the following picture shows connect successfully 8 Data transmission The first connection ID defaults to 0 AT CIPSEND 0 4 Sends 4 bytes of data to a connection with an ID of 0 Wait for input data without entering a new line Response Send OK ...

Page 16: ...cription 6 1 Network roles No Note 1 E103 W10 module supports AP mode equivalent to router STATION mode equivalent to Wi Fi device STATION AP mode and up to 10 Wi Fi devices at the same time in AP mode 2 E103 W10 supports three Socket roles TCP Server TCP Client and UDP Up to 5 Socket connections are supported simultaneously in TCP Server mode TCP based connectivity mechanisms if you need to be co...

Page 17: ... real time monitoring and other applications modules can be real time data exchange with the network server The user interacts with the network server to perform various operations on the module side in real time The module establishes TCP Server connection communication with Wi Fi devices in STATE mode The networking model is similar to the first one with the difference that the module is built i...

Page 18: ...STATION mode to communicate with each other The network model can be referred to simply as an intra module network an AP mode module can connect up to 10 RATIONAL that is in the network has a maximum of 9 module devices TCP Server can be built on any module under complete intranet completion and the remaining 10 modules can communicate with TCP Client but no more than 5 clients can access TCP Serv...

Page 19: ... Use the antenna to match the module poorly or the quality of the antenna itself is a problem 8 2 Module is easy to be damaged Please check the power supply to ensure that between the recommended supply voltage if the maximum value is exceeded the module will be permanently damaged Please check the stability of the power supply the voltage can not fluctuate significantly and frequently Make sure t...

Page 20: ... 4G 20 0 1 16 24 SMA TTL Profile Feature Sn Pb Assembly Pb Free Assembly Solder Paste Sn63 Pb37 Sn96 5 Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max Liquidous Temperature TL 183 217 Time tL Maintained Above TL 60 90 sec 30 90 sec Peak temperature T...

Page 21: ...requency Hz Interface Gain dBi Height mm Cable cm Function feature TX2400 NP 5010 Flexible antenna 2 4G 2 0 10x50 IPEX Flexible FPC soft antenna TX2400 JZ 3 Rubber antenna 2 4G 2 0 30 SMA J Short straight omnidirectional TX2400 JZ 5 Rubber antenna 2 4G 2 0 50 SMA J Short straight omnidirectional TX2400 JW 5 Rubber antenna 2 4G 2 0 50 SMA J Fixed bend omnidirectional TX2400 JK 11 Rubber antenna 2 4...

Page 22: ...1 0 2020 12 22 Initial version huaa 1 1 2021 01 12 Content adjusted Ren About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Phone 86 028 61399028 Web www ebyte com Address B5 Mould Park 199 Xiqu Ave High tech District Sichuan China ...

Reviews: