SI4463 wireless module
E10 series user manual
Copyright ©2012–2017,Chengdu Ebyte Electronic Technology Co.,Ltd.
11
3.3. E10-433MS1W
4. Notes
GPIO0 \ GPIO1 \ GPIO2 \ GPIO3 is general I/O,available for various functions. Please refer to SI4463 datasheet, they can be floated when free。
IRQ can be unconnected,the interrupt status can be acquired via SPI check mode, but it is recommended to connect with external MCU.
Make it ground well with large space for grounding and small power ripple. Filter capacitor is necessary and make sure it is close to pin VCC and
GND.
Air data rate for SPI shall not be too high,1Mbps is recommended.
Please refer to “Operating Modes and Timing” for status switch of SI4463,the switch between TX and RX must go through Ready,cannot be
switched directly.
One can reinitialize register setting when IC is free for better stability.
For external control of GPIO2 , GPIO3,status is as below:
When transmitting:GPIO2 = 0; GPIO3 = 1;
When receiving:GPIO2 = 1; GPIO3 = 0;
To control via SI4463, in the program initialization one can set pins as below:
SI44XX_GPIO_CONFIG( 0, 0, 32|0x40, 33|0x40, 0, 0, 0 );