![Ebyte E10-433MS1W User Manual Download Page 6](http://html.mh-extra.com/html/ebyte/e10-433ms1w/e10-433ms1w_user-manual_530468006.webp)
Chengdu Ebyte Electronic Technology Co., Ltd.
E10-433MS1W
User Manual
Copyright ©2012–2018
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
5
Pin
No.
Pin item
Pin direction
Pin application
1
GND
Input
Ground
2
SDN
Input
The module working enable control the pin,
its low level when working
(See SI4463 manual for more details)
3
GPIO3
Output
GPIO of SI4463
4
GPIO2
Output
GPIO of SI4463
5
nSEL
Input
SPI Chip select
6
MOSI
Input
SPI master input slave output
7
MISO
Output
SPI master output slave input
8
ENT
Input
Clock enable (high-level effective)
9
SCK
Output
SPI master input slave output
10
IRQ
Output
Interrupt request
11
GPIO1
Output
Output pin
12
GPIO0
Output
Output pin
13
VCC
Input
Power supply 3.3V~5.5V DC (Recommend 4.75~5.25V)
14
GND
Input
Ground
15
ENP
Input
PA power enable (High-level effective)
16
GND
Input
Ground
17
GND
Input
Ground
18
GND
Input
Ground
19
GND
Output
Ground
20
ANT
Output
Antenna
4.
Basic operation
4.1
Hardware design
l
It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible, and
the module needs to be reliably grounded.
;
l
Please pay attention to the correct connection of the positive and negative poles of the power supply. Reverse
connection may cause permanent damage to the module
;
l
Please check the power supply to ensure it is within the recommended voltage otherwise when it exceeds the
maximum value the module will be permanently damaged
;
l
Please check the stability of the power supply, the voltage can not be fluctuated frequently
;
l
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation.
;
l
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference.
;